AIRPLANE
OPERATIONS
MANUAL
GROUND SERVICING
REVISION 41
1-12-60
Page
25
Code
01
Copyright © by Embraer. Refer to cover page for details.
AOM
-
145/1114
ATA
EICAS
MESSAGE
or
CONDITION
LOCATION
PROCEDURE
31
CHECK IC
2 SW
EICAS
On the circuit breaker panel, open the
IC
2 circuit breaker and close it after
a few seconds.
31
DAU 1A
FAIL
EICAS
Check the SG pushbutton on the pilot
Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 1A FAIL message appears?
YES
−
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
NO
−
Open the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
−
Close the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.