GROUND SERVICING
AIRPLANE
O
PERATIONS
MANUAL
1-12-60
Page
26
Code
01
REVISION 41
Copyright © by Embraer. Refer to cover page for details.
AOM
-
145/1114
ATA
EICAS
MESSAGE
or
CONDITION
LOCATION
PROCEDURE
31
DAU 1B
FAIL
EICAS
Check the SG pushbutton on the pilot
Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 1B FAIL message appears?
YES
−
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
NO
−
Open the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
−
Close the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
31
DAU 2A
FAIL
EICAS
Check the SG pushbutton on the pilot
Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 2A FAIL message appears?
YES
−
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
NO
−
Open the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
−
Close the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.