AIRPLANE
OPERATIONS
MANUAL
GROUND SERVICING
REVISION 41
1-12-60
Page
27
Code
01
Copyright © by Embraer. Refer to cover page for details.
AOM
-
145/1114
ATA
EICAS
MESSAGE
or
CONDITION
LOCATION
PROCEDURE
31
DAU 2B
FAIL
EICAS
Check the SG pushbutton on the pilot
Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 2B FAIL message appears?
YES
−
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
NO
−
Open the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
−
Close the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
31
DAU 1
WRN
MISCOMP
EICAS
Check the SG pushbutton on the pilot
Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 1 WRN MISCOMP message
appears?
YES
−
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
N
O
−
Open the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.
−
Close the IC 1 circuit breaker on the
overhead circuit breakers panel and
the IC 1 circuit breaker on the
backup relay box.