AIRPLANE
OPERATIONS
MANUAL
EMERGENCY
PROCEDURES
MARCH 30, 2001
1-03-05
Page
3
Code
03
AIR CONDITIONING SMOKE
CONDITION: Smoke visually confirmed as being from the air
conditioning distribution, or identified by odor.
Suspect Bleed............................................................... CLOSE
Crossbleed.................................................................... OPEN
If procedure does not eliminate smoke, change bleed source supplying
the air conditioning (including APU bleed).
SMOKE EVACUATION and
CABIN FIRE OR SMOKE Procedures..................... AS REQUIRED
WARNING: IF IN ICING CONDITIONS, REFER TO SINGLE
ENGINE OR SINGLE BLEED OPERATION IN ICING
CONDITIONS PROCEDURE.
LAVATORY SMOKE
EICAS WARNING: LAV SMOKE
LIGHT: Master Warning
Lavatory Flush/Lavatory Light CB’s (E11 and E12) ......PULL
CABIN FIRE OR SMOKE Procedure............................ AS REQUIRED
BAGGAGE COMPARTMENT SMOKE
EICAS WARNING: BAGG SMOKE
LIGHT: Master Warning
Baggage Fire Extinguishing Button (if installed) ...........PRESS
Diversion ....................................................................... CONSIDER
Altitude .......................................................................... MAINTAIN
Maintain the current flight level as long as possible.
Alternate Airport ............................................................ IDENTIFY
Commence the diversion to land at the nearest suitable airport.
NOTE: - The extinguishing agent duration is approximately
50 minutes.
- Advise ground crew of possible presence of Halon vapors
and smoke trapped in the compartment.