EasyManua.ls Logo

Embraer EMB145 - Page 418

Embraer EMB145
2662 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EMERGENCY
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-05
Page
2
Code
03
REVISION 24
ELECTRICAL SYSTEM FIRE OR SMOKE
CONDITION: Smoke visually confirmed as being from electrical
source, or identified by odor.
If smoke source can be determined:
Electrical Power to Associated Equipment...............OFF
If smoke source cannot be determined:
Shed Buses..............................................................OFF
If smoke does not stop or decrease after a reasonable time, cut
power to Central DC Bus as follows:
Bus Ties ..............................................................OFF
APU Generator....................................................OFF
Battery 2..............................................................OFF
If smoke does not stop or decrease after a reasonable time, cut
power to DC Bus 1 and Essential DC Bus 1 as follows:
Ventral Pump Selector Button
(EMB-145XR only) .........................................SET TO B
Fuel Pumps.........................................................1B AND 2A OR
2C
Battery 2..............................................................AUTO
Battery 1..............................................................OFF
Generators 1 and 3 .............................................OFF
If smoke does not stop or decrease after a reasonable time, restore
power to the previously deenergized buses and cut power to DC
Bus 2 and Essential DC Bus 2 as follows:
Generators 1 and 3 .............................................ON
Battery 1..............................................................AUTO
Ventral Pump Selector Button
(EMB-145XR only) .........................................SET TO A
Fuel Pumps.........................................................2B AND 1A OR
1C
Battery 2..............................................................OFF
Generators 2 and 4 .............................................OFF
If smoke does not stop or decrease after a reasonable time, restore
power to the previously deenergized buses and cut power to
Backup Buses as follows:
Generators 2 and 4 .............................................ON
Battery 2..............................................................AUTO
APU Generator....................................................ON
Bus Ties ..............................................................AUTO
Shed Buses.........................................................AUTO
Backup Battery....................................................OFF
Land at the nearest suitable airport.
SMOKE EVACUATION
Procedure (if necessary) ..........................................ACCOMPLISH

Other manuals for Embraer EMB145