AIRPLANE
OPERATIONS
MANUAL
ABNORMAL
PROCEDURES
REVISION 40
1-03-45
Page
11
Code
03
AOM-145/1114
ENGINE ATS SHUTOFF VALVE OPEN
EICAS CAUTION: E1 (2) ATS SOV OPN
LIGHT: Master Caution
Associated Bleed (including APU bleed) ...................... CLOSE
Crossbleed.................................................................... CLOSE
On ground:
Associated Thrust Lever.......................................... IDLE
Associated Start/Stop .............................................. STOP
If engine shutdown dows not occur:
Fire Extinguishing Handle ................................ PULL (DO NOT
ROTATE)
In flight:
Altitude..................................................................... MAX 25000 ft
Exit and avoid icing conditions.
ENGINE REFERENCE ANTI-ICE DISAGREE
EICAS CAUTION: ENG REF A/I DISAG
LIGHT: Master Caution
Check ice protection system selection against takeoff data entered.
ENGINE OVERTEMPERATURE
EICAS Indication: ITT pointer and digits become red and flash.
Confirm the affected side.
Associated Thrust Lever ............................................... REDUCE
If the condition remains:
Associated Bleed..................................................... CLOSE
Check the associated BLD VLV CLSD message on EICAS:
Altitude..................................................................... MAX 25000 ft
MINIMUM MEA
TCAS ....................................................................... TA ONLY
If the conditions remains:
PRECAUTIONARY ENGINE SHUTDOWN or
ENGINE FIRE, SEVERE DAMAGE OR
SEPARATION Procedure ............................. ACCOMPLISH

Other manuals for Embraer EMB145