AIRPLANE
OPERATIONS
MANUAL
ABNORMAL
PROCEDURES
REVISION 41
1-03-56
Page
1
Code
03
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
AIR CONDITIONING, PNEUMATICS AND
PRESSURIZATION
BLEED LOW TEMPERATURE
EICAS Caution: BLD 1 (2) LOW TEMP
LIGHT: Master Caution
INDICATION: Pointer on MFD may be out of view or indication may be
amber.
If temperature indication on MFD (ECS and Pneumatic Page) is in the
green range or the pointer is out of view, disregard the message.
Monitor the bleed temperature.
If the pointer on MFD indicates low temperature (white range):
Associated Thrust Lever.......................................... ADVANCE
Adjust associated Thrust Lever until the message disappears or
until the pointer of the failed side reaches the green range or the
remaining pointer.
Advancing Thrust Lever until 86% N2 represents normal system
condition.
If the message persists or if the MFD is not available:
Associated Bleed..................................................... CLOSE
Altitude..................................................................... MAX 25000 ft
MINIMUM MEA
WARNING:
IF IN ICING CONDITIONS, REFER TO SINGLE
ENGINE OR SINGLE BLEED OPERATION IN ICING
CONDITIONS PROCEDURE.
If the message persists, avoid or exit icing conditions.
NOTE: Ice Detection Override Knob must be set to ALL at least
2 minutes after exiting icing conditions or after ICE
CONDITION advisory message has disappeared.