ABNORMAL
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-56
Page
2
Code
03
REVISION 41
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
HIGH STAGE VALVE FAILURE
EICAS Caution: HS VLV 1 (2) FAIL
LIGHT: Master Caution
Monitor bleed temperature.
If the bleed temperature is too high:
BLEED OVERTEMPERATURE
Procedure ........................................................... AS REQUIRED
If the bleed temperature is too low:
BLEED LOW TEMPERATURE
Procedure ........................................................... AS REQUIRED
WARNING:
IF IN ICING CONDITIONS, REFER TO SINGLE
ENGINE OR SINGLE BLEED OPERATION IN ICING
CONDITIONS PROCEDURE.
BLEED VALVE FAILURE
EICAS Caution: BLD 1 (2) VLV FAIL
LIGHT: Master Caution
If BLD 2 VLV CLSD message is also displayed on the EICAS:
Crossbleed............................................................... OPEN
Altitude ..................................................................... MAX 25000 ft
MINIMUM MEA
If BLD 1 VLV CLSD message is also displayed on the EICAS:
If APU is not serviceable:
Crossbleed.......................................................... OPEN
Altitude ................................................................ MAX 25000 ft
MINIMUM MEA
If APU is serviceable:
Crossbleed.......................................................... CLOSE
APU..................................................................... START
APU Bleed .......................................................... OPEN
WARNING:
IF IN ICING CONDITIONS, REFER TO SINGLE
ENGINE OR SINGLE BLEED OPERATION IN ICING
CONDITIONS PROCEDURE.
If BLD 1(2) VLV CLSD message is not displayed on the EICAS:
Monitor the system for the remainder of the flight.