Do you have a question about the Emerson Quiet Kool EARC8RE1A and is the answer not in the manual?
FCC compliance rules and potential interference issues.
Room size requirements for R32 refrigerant capacity.
Essential grounding methods and LCDI power cord functionality.
List of all items provided in the air conditioner package.
Installation procedures for 6K/8K and 10K/12K models.
Step-by-step instructions for attaching the top rail to the unit.
Hardware list and guide for installing the air conditioner in a window.
Advice on storm windows and safe unit removal.
Explanation of control panel and remote features and operation.
Description of expected sounds during normal operation.
Details on Eco, Sleep, Fan Speed, Filter check, and Louver functions.
Explains the function of each button on the remote control.
Filter cleaning, unit cleaning, storage, and wear prevention tips.
Solutions for unit not starting or cooling issues.
Troubleshooting tips for remote control and coil freezing problems.
Explanations and solutions for water dripping and base pan collection.
This document serves as a user manual for the EQK Emerson Quiet Kool Electronic Window Air Conditioner, providing comprehensive instructions for its installation, operation, and maintenance. The air conditioner is designed to offer high-efficiency cooling with portable convenience, suitable for various room sizes depending on the model.
The EQK Electronic Window Air Conditioner is primarily designed to cool a room and reduce humidity, making the indoor environment more comfortable. It operates using environmentally friendly R32 refrigerant. The unit features multiple operating modes, including Cool, Dry, Fan, and Auto, to cater to different user preferences and environmental conditions.
In Cool Mode, the air conditioner actively cools the room and dehumidifies the air. Users can adjust the temperature and fan speed to optimize cooling performance. The Dry Mode focuses on reducing humidity, which can make a room feel more comfortable even without significant temperature reduction. This mode activates an automatic function of alternating cooling cycles and air fan operation. The Fan Mode circulates air without cooling, providing ventilation. Users can select from high, medium, or low fan speeds. The Auto Mode intelligently selects the appropriate fan speed and operating mode (Cool, Dry, or Fan) based on the room temperature, which is detected by a sensor in the indoor unit.
The air conditioner also includes a Timer function, allowing users to program the unit to turn on or off automatically at a specified time. This feature can be set for intervals ranging from 0.5 to 24 hours, providing convenience and energy savings. An ECO Mode is available to enhance energy efficiency. In this mode, the unit turns off once the room reaches the user-set temperature and turns back on when the temperature rises above that setting. Before the compressor starts, the fan motor runs for a while, stops, and then repeats, aiming to provide comfort while conserving energy. A Sleep Mode is designed for nighttime comfort, automatically adjusting the temperature and fan speed to create a more comfortable sleeping environment. In this mode, display lights turn off, but the Sleep light remains on. The set temperature gradually increases over 30-60 minute intervals, up to a maximum of 81 or 82°F for cooling.
For user convenience, the unit is equipped with Directional Louvers that allow control over horizontal and vertical airflow, enabling users to direct the cool air where it's most needed. A Filter Check light serves as a reminder to clean the air filter after 500 hours of operation, ensuring optimal performance and air quality.
The air conditioner can be controlled via an electronic control panel located on the unit or through a remote control. Both interfaces offer similar functionalities, including power on/off, mode selection, temperature adjustment, and timer settings. The digital display on the unit shows the set temperature and current operating mode.
Temperature Adjustment: Users can increase or decrease the set temperature using dedicated buttons, with a temperature range of 61°F to 88°F (16°C to 31°C).
Fan Speed Control: In Cool Mode, fan speeds can be set to HI, MED, LO, or AUTO. In Fan Mode, options include HI, MED, and LO.
Timer Settings: The timer can be programmed for both timed stop (Timer Off) and timed start (Timer On). For Timer Off, users set the desired stop time. For Timer On, when the unit is off, users first set the temperature, then the start time, and confirm the settings. The display will show the time the machine will automatically turn on. The timer can be adjusted in 0.5-hour increments for settings below 10 hours and 1-hour increments for settings of 10 hours or more. The SET light illuminates during timer setup. To cancel the timer function, the TIMER button is pressed again.
Display Control: A DISPLAY button on the remote control allows users to switch off/on all lights or the LED display on the unit.
Safety Features: The unit is equipped with an LCDI (Leakage Current Detection and Interruption) power cord, which senses leakage current and disconnects power if detected. Test and reset buttons on the LCDI plug allow users to verify its proper functioning. Important safety instructions emphasize plugging into a grounded 3-prong outlet, not removing the ground prong, and avoiding plug adapters or extension cords. Unplugging the unit before servicing is also highlighted.
Installation: The air conditioner is designed for installation in standard double-hung windows. Specific window width and vertical clearance requirements are provided for different models (6K/8K and 10K/12K). The manual details the assembly of the top rail and side panels, and securing the unit in the window frame using screws and a sash lock. It also provides guidance on how to handle storm windows if they obstruct installation.
Regular maintenance is crucial for the air conditioner's longevity and efficient operation.
Air Filter Cleaning: The air filter should be checked at least once a month for cleaning. The Check Filter light automatically illuminates after 500 hours of fan motor operation as a reminder. To clean the filter, it is removed by pulling down on the indents of the filter door, washed with liquid dish soap and warm water, rinsed thoroughly, gently shaken to remove excess water, and allowed to dry completely before reinstallation. Alternatively, the filter can be vacuumed to remove dust and particles.
Cabinet Cleaning: To clean the air conditioner cabinet, the unit must first be unplugged to prevent electrical shock. The cabinet and front panel can be dusted with an oil-free cloth or wiped with a cloth dampened in a solution of warm water and mild liquid soap. It should then be rinsed thoroughly with a damp cloth and wiped dry. Harsh cleaners, wax, or polish should not be used on the cabinet front. Care must be taken to wring excess water from the cloth before wiping around the controls to prevent damage.
Wear and Tear Prevention: To minimize wear and tear on the compressor and prevent circuit breaker trips, it is recommended to wait at least 3 minutes before changing operating modes.
Winter Storage: For extended periods of non-use, the air conditioner should be carefully removed from the window according to the installation instructions, covered with plastic, or stored in its original box.
Troubleshooting: The manual includes a troubleshooting section to help users address common issues such as the unit not starting, not cooling properly, freezing up, or the remote control not working. Solutions range from checking power connections and circuit breakers to cleaning the filter, adjusting thermostat settings, and ensuring proper drainage. For instance, if water is dripping inside the room, it suggests ensuring the air conditioner is slightly tilted downward from the front to the rear for proper drainage. If the unit is freezing up, it advises setting the MODE dial to HIGH FAN or HIGH COOL and increasing the thermostat temperature.
| Type | Window Air Conditioner |
|---|---|
| Cooling Capacity | 8000 BTU |
| Voltage | 115V |
| Noise Level | 52 dB |
| Cooling Area | 350 sq. ft. |
| Fan Speeds | 3 |
| Window Type | Double Hung |
| Remote Control | Yes |
| Power Supply | 115V/60Hz |
| Noise Level (Indoor) | 52 dB |
| Refrigerant | R32 |
| Control Type | Electronic |