EasyManua.ls Logo

Emerson Dixell XB570L - How Modify a Cycle

Emerson Dixell XB570L
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1592006207 XB570L GB r1.1 23.03.2015 XB570L 3/20
HOW DISPLAY / MODIFY THE SET
POINT OF THE HOLDING PHASE
- TO DISPLAY: p
ush and
release the SET key (6)
, the
holding
set point of the
select
ed cycle is displayed for
5 sec.
- TO MODIFY:
while the set
point is displayed hold pushed
the SET key till the HdS label
start flashing. Use the UP and
DOWN key to modifiy the
value..
TO CONFIRM:
push the SET key to
confirm the value and exit.
In this example
the
holding set point of the
cycle 1 is modified.
In this example
the set point of
the holding
cycle is
modified.
HOW MODIFY A CYCLE:
1. Push the
key (6) for several
seco
nds till the first parameter (CyS)
is displayed.
2.
Use the UP and DOWN keys to
browse the parameters.
3.
To modify a parameter push the SET
key and use the arrow keys.
4.
Confirm the new value by pushing the
SET key.
5. The new value is recorded even if the
programming is exited by time out.
8.3 KEYBOARD WHEN A CYCLE 1,2,3,4 IS RUNNING
DISPLAY TEMPERATURES:
The upper
display shows the
temperature of the thermostat probe
The bottom
display shows the
temperature of a insert probe (if
enabled) or the count down timer.
By pushing DOWN key,
the probes
iP1, iP2, iP3 and the count-
down timer
are displayed in sequence.

Related product manuals