1592023130 XM670K_XM679K GB r4.2 26.06.2017.docx XM670K - XM679K 9/10
0 ÷ 42.0(252) (min.10sec)
Opening percentage after defrost
phase
Post defrost function duration
0 ÷ 42.0(252) (min.10sec)
Maximum opening percentage at
normale functioning
Delay before stopping valve
regulation
Forced opening percentage
Probe value at 4 mA or at 0V
BAR : [PrM=rEL] -1.0 ÷ P20
[PRM=Abs] 0.0 ÷ P20
PSI : [PrM=rEL] -14 ÷ P20
[PRM=Abs] 0 ÷ P20
dKP : [PrM=rEL] -10 ÷ P20
[PRM=Abs] 0 ÷ P20
Probe value at 20 mA or at 5V
BAR : [PrM=rEL] PA4 ÷ 50.0
[PrM=AbS] PA4 ÷ 50.0
PSI : [PrM=rEL] PA4 ÷ 725
[PrM=AbS] PA4 ÷ 725
dKP : [PrM=rEL] PA4 ÷ 500
[PrM=AbS] PA4 ÷ 500
Lower pressure limit for superheat
regulation
Maximum operating pressure
threshold
Lowest operating pressure
threshold
Delta MOP-LOP opening variation
Maximum superheat alarm
threshold
[LSH ÷ 80,0°C] [LSH ÷ 144°F]
Minimum superheat alarm
threshold
[0.0 ÷ MSH °C] [0 ÷ MSH °F]
Superheat alarm hysteresis
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Superheat alarm activation delay
0 ÷ 42.0(252) (min.10sec)
nP(0) - P1(1) - P2(2) - P3(3) -
P4(4) - P5(5)
nP(0) - P1(1) - P2(2) - P3(3) -
P4(4) - P5(5)
Virtual probe percentage (defrost
temperature)
Defrost mode: Clock or interval
Heater set point during defrost
[-55.0°C ÷ 150°C] [-67°F ÷
302°F]
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Minimum temperature difference
to start defrost
[0.1°C ÷ 50.0°C] [1°F ÷ 90°F]
Delay before starting defrost
Defrost termination temperature
(Probe A)
[-55.0°C ÷ 50.0°C] [-67°F ÷
122°F]
Defrost termination temperature
(Probe B)
[-55.0°C ÷ 50.0°C] [-67°F ÷
122°F]
Interval between defrosts
rt(0) - it(1) - SEt(2) - dEF(3)
Defrost delay after continuous
cycle
0 ÷ 24.0(144) (hours.10min)
nP(0) - P1(1) - P2(2) - P3(3) -
P4(4) - P5(5)
nP(0) - P1(1) - P2(2) - P3(3) -
P4(4) - P5(5)
Virtual probe percentage (fan
management)
C-n(0) - O-n(1) - C-y(2) - O-y(3)
Temperature differential to avoid
short cycles of fans
[0.0°C ÷ 50.0°C] [0°F ÷ 90°F]
[-55.0°C ÷ 50.0°C] [-67°F ÷
122°F]
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Fan activation time after defrost
(without compressor)
Kind of regulation for modulating
output
[-55.0°C ÷ 50.0°C] [-67°F ÷
122°F]
Differential for fan / offset for anti
sweat heater
[-25.5°C ÷ 25.5°C] [-45°F ÷ 45°F]
Proportional band for modulating
output
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Minimum output for modulating
output
Maximum output for modulating
output
Time with fan at maximum speed
Probe for temperature alarm
nP(0) - P1(1) - P2(2) - P3(3) -
P4(4) - P5(5) - tEr(6)
Temperature alarm configuration
High temperature alarm setting
[0.0°C ÷ 50.0°C o ALL ÷ 150.0°]
[0°F ÷ 90°F o ALL ÷ 302°F]
Low temperature alarm setting
[0.0°C ÷ 50.0°C o -55,0°C ÷
ALU] [0°F ÷ 90°F o -67°F ÷
ALU°F]
Differential for temperature alarm
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
High temperature alarm setting
(defrost probe)
[0.0°C ÷ 50.0°C o dLL ÷ 150.0°]
[0°F ÷ 90°F o dLL ÷ 302°F]
Low temperature alarm setting
(defrost probe)
[0.0°C ÷ 50.0°C o -55,0°C ÷
dLU] [0°F ÷ 90°F o -67°F ÷
dLU°F]
Differential for temperature alarm
(defrost probe)
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Temperature alarm delay (defrost
probe)
High temperature alarm setting
(fan probe)
[0.0°C ÷ 50.0°C o FLL ÷ 150.0°]
[0°F ÷ 90°F o FLL ÷ 302°F]
Low temperature alarm setting
(fan probe)
[0.0°C ÷ 50.0°C o -55,0°C ÷
FLU] [0°F ÷ 90°F o -67°F ÷
FLU°F]
Differential for temperature alarm
(fan probe)
[0.1°C ÷ 25.5°C] [1°F ÷ 45°F]
Temperature alarm delay (fan
probe)
Delay of temperature alarm at
start-up
0 ÷ 24.0(144) (hours.10min)
Alarm delay at the end of defrost
Temperature alarm exclusion after
door open
"nu"(0) ÷ 24.0(144)
(hour.10min)
Sixth relay output configuration
CPr(0) - dEF(1) - FAn(2) - ALr(3)
- LiG(4) - AUS(5) - db(6) -
OnF(7)
Modulating output configuration
CUr(0) - tEn(1) - PM5(2) -
PM6(3) - oA7(4)
Auxiliary output indipendent from
ON/OFF state
Digital input 1 configuration
EAL(0) - bAL(1) - PAL(2) - dor(3)
- dEF(4) - AUS(5) -LiG(6) -
OnF(7) - Htr(8) - FHU(9) -
ES(10) - Hdy(11)
Digital input 1 activation delay
Digital input 2 configuration
EAL(0) - bAL(1) - PAL(2) - dor(3)
- dEF(4) - AUS(5) -LiG(6) -
OnF(7) - Htr(8) - FHU(9) -
ES(10) - Hdy(11)
Digital input 2 activation delay
Digital input 3 configuration
EAL(0) - bAL(1) - PAL(2) - dor(3)
- dEF(4) - AUS(5) -LiG(6) -
OnF(7) - Htr(8) - FHU(9) -
ES(10) - Hdy(11)
Digital input 3 activation delay
Number of pressure switch
activation before lock
Compressor and fan status when
open door
no(0) - FAn(1) - CPr(2) - F-C(3)
Outputs restart after door open
alarm