5-2 L3314EA
2. Initial Setting
General
1. Enter the Service mode. (See page 5-1.)
2. Press [VOL p] button on the service remote
control unit. Display changes “C/D,” “7F,
“LANGUAGE,” “ACCESS CODE,” “SOUND TYPE,
“VIDEO TONE,” “FM-MODE,” “V-OUT,” “VIDEO,
“AV MEMO,” “STABLE SOUND,” “FILTER,” “1000,
“YUV MEMORY,” “NO SIG BRT,” “A-MUTE POL,
and “V-MENU” cyclically when [VOL p] button is
pressed.
3. To set the following each data value, press [CH o /
p] buttons on the service remote control unit.
7F --- Set to “FF.
LANGUAGE --- Set to “SPA/FRA.
ACCESS CODE --- Set to “ON.
SOUND TYPE --- Set to “MTS.
VIDEO TONE --- Set to “ON.
FM-MODE --- Set to “OFF.
V-OUT --- Set to “OFF.
VIDEO --- Set to “V1/V2.
AV MEMO --- Set to “OFF.
STABLE SOUND --- Set to “OFF.
FILTER --- Set to “OFF.
Adjusting the monitoring time --- Set to “1000.
YUV MEMORY --- Set to “OFF.
NO SIG BRT --- Set to “0.
A-MUTE POL --- Set to “H.
V-MENU --- Set to “OFF.
3. Setting for BRIGHT, CONTRAST,
COLOR, S-COLOR, TINT, V-TINT,
S-TINT, SHARP, and S-SHARP
Data Values
General
1. Enter the Service mode. (See page 5-1.)
2. Press [MENU] button on the service remote
control unit. Display changes “BRT,” “CNT,” “CLR,
“S-CLR,” “TNT,” “V-TNT,” “S-TNT,” “SHARP,” and
“S-SRP,” cyclically when [MENU] button is
pressed.
CNT
1. Press [MENU] button on the service remote
control unit. Then select “CONTRAST” (CNT)
display.
2. Press [CH o / p] buttons on the service remote
control unit so that the value of “CONTRAST”
(CNT) becomes 84.
CLR
1. Press [MENU] button on the service remote
control unit. Then select “COLOR” (CLR) display.
2. Press [CH o / p ] buttons on the service remote
control unit so that the value of “COLOR” (CLR)
becomes 58.
S-CLR
1. Press [MENU] button on the service remote
control unit. Then select “S-COLOR” (S-CLR)
display.
2. Press [CH o / p ] buttons on the service remote
control unit so that the value of “S-COLOR” (S-
CLR) becomes 58.
TNT
1. Press [MENU] button on the service remote
control unit. Then select “TINT” (TNT) display.
2. Press [CH o / p ] buttons on the service remote
control unit so that the value of “TINT” (TNT)
becomes 60.
V-TNT
1. Press [MENU] button on the service remote
control unit. Then select “V-TINT” (V-TNT) display.
2. Press [CH o / p ] buttons on the service remote
control unit so that the value of “V-TINT” (V-TNT)
becomes 60.
S-TNT
1. Press [MENU] button on the service remote
control unit. Then select “S-TINT” (S-TNT) display.
2. Press [CH o / p ] buttons on the service remote
control unit so that the value of “S-TINT” (S-TNT)
becomes 60.
SHARP
1. Press [MENU] button on the service remote
control unit. Then select “SHARP” (SHARP)
display.
2. Press [CH o / p ] buttons on the service remote
control unit and select “43.
S-SRP
1. Press [MENU] button on the service remote
control unit. Then select “S-SHARP” (S-SRP)
display.
2. Press [CH o / p ] buttons on the service remote
control unit and select “43.
Note: BRIGHT data value does not need to be
adjusted at this moment.