24 Installation
Use the following bolt installation procedure:
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated with a
lubricant to ease installation. Do not apply any additional lubricant when installing either
type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See Table 2-3 for initial
torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See Table 2-3 for
final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying pressure.
able 2-3. Torque Values for the Flange and Flange Adapter Bolts
Bolt Material
Head markings
Initial Torque
Final Torque
Carbon Steel (CS)
300 in. -lbs.
(33.9 N m)
650 in. -lbs.
(73.4 N m)
Stainless Steel
(SST)
150 in. -lbs.
(16.9 N m)
300 in. -lbs.
(33.9 N m
Figure 2-13. Proper Bolt Installation
1
Bolt
2
Sensor module

Table of Contents