Emerson FB2200 Flow Computer Instruction Manual
D301784X012
March 2019
48 Installation
5. Use the solar controller lock nut to attach the solar controller to the junction box and use a
7/32” flat head screwdriver to attach the wires from the controller to the junction box
connectors as shown.
Figure 2-36. Wiring Solar Power External Regulator
6. Route the BATT+ and BATT wires from the flow computer into the junction box.
Figure 2-37. Routing Battery Wires
7. Connect the wires as shown. Replace the junction box cover.