Figure 4. Fisher 1066 Assembly Detail
LEVER &
BEARING
ASSEMBLY
HUB &
BEARING
ASSEMBLY
MOUNTING
YOKE (KEY 25)
BEARING
(KEY 4)
O-RING
(KEY 18)
HOUSING
(KEY 1)
CYLINDER
COVER
(KEY 2)
W4100-1
ACTUATOR
MOUNTING SCREWS
PISTON
(KEY 3)
PISTON
ROD
(KEY 5)
O-RING
(KEY 17)
CYLINDER
(KEY 8)
W4101-1
TOP LOADING
PRESSURE CONNECTION
BOTTOM LOADING
PRESSURE
CONNECTION
SEE SPECIAL
WARNING
LOCKNUT
(KEY 37)
ACTUATOR
TRAVEL
STOPS
2. Lower the piston rod with attached lever and bearing assembly into the actuator housing.
3. Apply lithium grease lubricant (key 35) to the outer surface of the hub (key 6). Orient the hub (key 6) so that one of
the index holes on the end of the hub is in line with the lever pin (key 9). Then, slide the hub into the housing and
through the lever and bearing assembly.
4. Apply lithium grease lubricant (key 35) to the outer surface of the bearing (key 4). Then, install the bearing and
washer (keys 4 and 43) into the housing as shown in figure 6 or 7.
5. Securethemountingyoketotheactuatorwiththecapscrews(key20).Tightenthecapscrewsto25NSm(18
lbfSft) for size 20 and 27 actuators and to 102 NSm(75lbfSft) for size 75 actuators.
6. Theindexmarkonthevalveshaftmustbealignedwithoneofthefourindexholesontheendoftheactuatorhub
(key 6). Consult the appropriate valve instruction manual for lever/shaft index mark (hole) orientations for various
positions. Then, slide the actuator onto the valve shaft.
7. Bolt the mounting yoke to the valve with the mounting bolts provided with the control valve. For 9500 valves, bolt
themountingyoketothevalvewiththecapscrewsandflatwashers(key36and38,notshown)suppliedwiththe
actuator.
8. Apply lithium grease lubricant (key 35) to the wall of the cylinder (key 8), to the cap screw (key 19), and to the
O-ring (key 17) as shown in figure 6 or 7.
9. Install the spring (key 7). Then, attach the piston (key 3) to the piston rod (key 5) with the cap screw (key 19) and
sealing washer (key 11). For size 20 actuators, install a flat washer (key 23) with these parts. Tighten the cap screw
to 81 NSm(60lbfSft) for size 20 actuators, 136 NSm(100lbfSft) for size 27, and 176 NSm(130lbfSft) for size 75
actuators.