Introduction
This installation guide provides instructions for installation, 
startup and adjustment. To receive a copy of the 
instruction manual, contact your local Sales Office or view 
a copy at www.fisher.com. For further information refer to: 
Type 92S Instruction Manual, D100637X012.
PED Categories
This product may be used as a safety accessory with 
pressure equipment in the following Pressure Equipment 
Directive categories. It may also be used outside of the 
Pressure Equipment Directive using sound engineering 
practice (SEP) per table below. For information on the 
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/4 NPT SEP 1
Specifications
Maximum Inlet and Outlet Pressures
(1)
See Table 2
Outlet Pressure Ranges
See Table 1
Proof Test Pressure
All Pressure Retaining Components have been 
proof tested per Directive.
Maximum Temperature Capabilities
Cast Iron: 208°C / 406°F
Steel: 260°C / 500°F
Optional High Temperature Steel and Stainless 
Steel Construction: 343°C / 650°F
Installation
!
WARNING
Only qualified personnel should install 
or service a regulator. Regulators 
should be installed, operated and 
maintained in accordance with 
international and applicable codes 
and regulations and Emerson Process 
Management Regulator Technologies, 
Inc. instructions. 
If the regulator vents fluid or a leak 
develops in the system, it indicates that 
service is required. Failure to take the 
regulator out of service immediately may 
create a hazardous condition.
Personal injury, equipment damage or 
leakage due to escaping fluid or bursting 
of pressure-containing parts may result 
if this regulator is overpressured or 
is installed where service conditions 
could exceed the limits given in the 
Specifications section, or where 
conditions exceed any ratings of the 
adjacent piping or piping connections.
To avoid such injury or damage, provide 
pressure-relieving or pressure-limiting 
devices (as required by the appropriate 
code, regulation or standard) to 
prevent service conditions from 
exceeding limits. 
Additionally, physical damage to the 
regulator could result in personal injury 
and property damage due to escaping 
fluid. To avoid such injury and damage, 
install the regulator in a safe location.
Clean out all pipelines before installation of the 
regulator and check to be sure the regulator has not 
been damaged or has collected foreign material during 
shipping. For NPT bodies, apply pipe compound to 
the external pipe threads. For flanged bodies, use 
suitable line gaskets and approved piping and bolting 
practices. Install the regulator in any position desired, 
unless otherwise specified, but be sure flow through 
the body is in the direction indicated by the arrow on 
the body.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded. 
Table 1. Outlet (Control) Pressure Ranges
PILOT TYPE
OUTLET PRESSURE RANGE
bar psig
6492L
0.14 to 0.41 2 to 6
0.34 to 1.0 5 to 15
0.90 to 1.7 13 to 25
6492H
0.69 to 2.1 10 to 30
1.7 to 5.2 25 to 75
4.8 to 10.3 70 to 150
6492HT
1.0 to 6.9 15 to 100
5.5 to 17.2 80 to 250
Type 6492
Installation Guide
D103055X014
English – October 2013