14
Figure 5. Typical Fisher EUT‐2 or EWT‐2 Valve
E1488
SEAL RING FOR
EUT‐2 AND EWT‐2 VALVE PLUGS
CAGE
(KEY 3)
VALVE
PLUG
(KEY 2)
SEAL
RING
(KEY 28)
NOTE:
SEAL RING OPENING MUST FACE SEAT RING FOR FLOW DOWN APPLICATIONS AND MUST FACE ACTUATOR FOR FLOW UP APPLICATIONS
1
VIEW A
A
CAUTION
Never reuse an old stem (key 7) with a new valve plug. Using an old stem with a new plug requires drilling a new pin hole in
the stem. This weakens the stem and may cause it to fail in service. However, a used valve plug may be reused with a new
stem.
4. To replace the valve stem (key 7), drill out the pin (key 8) and unscrew the stem from the valve plug.