EasyManua.ls Logo

Emerson Liebert Intellislot Unity Card User Manual

Emerson Liebert Intellislot Unity Card
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Liebert
®
IntelliSlot Unity Card
User Manual—Web, SNMP, Modbus, BACnet, YDN23

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson Liebert Intellislot Unity Card and is the answer not in the manual?

Emerson Liebert Intellislot Unity Card Specifications

General IconGeneral
BrandEmerson
ModelLiebert Intellislot Unity Card
CategoryComputer Hardware
LanguageEnglish

Summary

Important Safety Instructions

1.0 Introduction

1.1 Protocols

Lists available communication protocols like BACnet IP, Modbus TCP/RTU, SNMP, YDN23.

1.2 Compatibility With Other Emerson Products and Communication Protocols

Details compatibility with various Liebert equipment and supported protocols.

1.3 Support for Liebert SN Sensors

Describes the connection and monitoring of Liebert SN sensors.

2.0 Installation

2.1 Installing the Liebert IntelliSlot Unity Card

Instructions for physical installation of the card into Liebert equipment.

2.1.1 Assigning the Card's IP Address

Methods for assigning an IP address to the card (DHCP or Static IP).

2.1.2 Connect an Ethernet Cable

Steps to connect the card to a computer via Ethernet for configuration.

2.1.3 Connect an RS-485 Serial Cable

Instructions for connecting the card using an RS-485 serial cable.

2.2 Change User Names and Passwords Immediately

Guidance on changing default administrator and user credentials for security.

2.3 Configure the Card

Steps for basic card configuration, including IP/Web communication interface.

2.4 Installing Multiple Liebert IntelliSlot Unity Cards in a System

Procedures to avoid conflicts when installing more than one card.

2.5 Security Best Practices

Recommendations for securing the Unity card and critical infrastructure equipment.

3.0 Enable Communication Protocols

3.1 Enable Protocols

Steps to enable communication protocols like BACnet, Modbus, SNMP, YDN23.

3.1.1 Enable Modbus Protocol

Process for enabling the Modbus protocol (TCP or RTU).

3.1.2 Enable BACnet Protocol

Steps to enable the BACnet protocol (IP or MSTP).

3.1.3 Enable SNMP

Steps to enable and configure SNMP settings.

3.2 Download Protocol Mappings

How to download data mapping files for protocols.

4.0 Liebert IntelliSlot Unity Card Web Page Layout

4.1 Web Page Sections

Describes the main areas of the web interface: Identification, Status, Tab Menus, Detail.

4.2 Help Text

Explains how to use help text and icons within the web interface.

4.3 Managed Device Tab Menus

Details the menus available on the Managed Device tab.

4.4 Communications Tab Menus

Details the menus available on the Communications tab.

4.5 Sensor Tab Menus—Shown Only if a Sensor is Connected

Describes the Sensor tab, visible when sensors are connected.

4.5.1 Sensor Tab Summary Page

Details the Sensor tab's summary page layout and options.

4.5.2 Sensor Tab Summary Page-Details Pane

Explains the details pane for selected sensors on the summary page.

4.6 Changing Sensor Order

Instructions for reordering sensor display.

5.0 Editing the Liebert IntelliSlot Unity Card Configuration

5.1 Communications Tab Folders

Overview of the Communications tab and its subfolders.

5.2 Communications—Active Events Folder

Describes the Active Events folder in the Communications tab.

5.3 Communications—Downloads Folder

Describes the Downloads folder for log files.

5.4 Communications—Configuration Folder

Introduces the Configuration folder and its subfolders.

5.4.1 Configuration—System Folder

Settings for system information like name, location, and temperature units.

5.4.2 Configuration—User Folder

Settings for administrator and general user names and passwords.

5.4.3 Configuration—Network Folder

Network settings including Speed Duplex, Domain Name Suffix, Telnet Server.

5.4.4 Configuration—Web Server Folder

Security settings for the web server (HTTP/HTTPS, password protection).

5.4.5 Configuration—LIFE™ Folder

Settings for Emerson® LIFE Technology remote monitoring.

5.4.6 Configuration—Emerson Protocol Folder

Configuration options for the Emerson Protocol.

5.4.7 Configuration—Messaging Folder

Settings for enabling email and text messaging about events.

5.5 Communications—Protocols Folder

Overview of available communication protocols.

5.5.1 Protocols—BACnet Folder

Configuration settings for BACnet protocol.

5.5.2 Protocols—Modbus Folder

Configuration settings for Modbus protocol.

5.5.3 Protocols-SNMP Folder

Configuration settings for SNMP protocol.

5.5.3.1 SNMPv3 User Folder

Configuration for SNMPv3 user accounts.

5.5.3.3 SNMPv1 Trap Folder

Settings for SNMPv1 trap targets.

5.5.3.4 SNMPv1/v2c Access Folder

Settings for SNMPv1/v2c access hosts.

5.5.4 Protocols-YDN23 Folder

Configuration settings for the YDN23 protocol.

5.6 Communications—Status Folder

Displays system status and events affecting the card.

5.7 Communications—Support Folder

Provides access to card restart, factory reset, and firmware updates.

5.7.1 Support—Active Networking Folder

Displays active IP network settings for troubleshooting.

5.7.2 Support-Firmware Update Folder

Supports updating or reverting card firmware.

6.0 Firmware Updates

6.1 Updating the Liebert IntelliSlot Unity Card's Firmware

Steps to download and install new firmware for the card.

6.2 Revert to Alternate Firmware

Procedure to revert to a previously stored firmware version.

Appendix A - Configuration Folder—LIFE™ Sub Folder

Technical Support | Service

Related product manuals