User Manual -Intelligent Communications & Monitoring for Liebert DSE
with
Software Version PA2.03.33R

Table of Contents

Other manuals for Emerson Liebert iCOM

Questions and Answers

  • B
    Bob AustinJul 31, 2025
    How to troubleshoot an Emerson Air Conditioner blower that will not start?
    • L
      leematthewJul 31, 2025
      If the blower on your Emerson Air Conditioner won't start, there are several potential causes: * **No main power:** Verify that L1, L2, and L3 have the rated voltage. * **Blown fuse or tripped circuit breaker:** Inspect the fuses or circuit breakers connected to the main fan and replace/reset if necessary. * **Overloads tripped:** Push the reset button on the main fan overload. Also, check the amp draw. * **No output voltage from transformer:** Check for 24 VAC between P24-2 and P24-1. If there is no voltage, check the primary voltage. * **Control fuse blown or circuit breaker tripped:** Check for 24 VAC between P4-4 and E1. If there is no voltage, check for a short. Replace the fuse or reset the circuit breaker.
  • D
    Daniel WheelerAug 6, 2025
    How to check power to actuator motors in Emerson Air Conditioner?
    • M
      michele18Aug 6, 2025
      If the actuator motor in your Emerson Air Conditioner isn't working, the issue might be a lack of power. Check for 24 VAC between P22-3 and P22-5 (open), or P22-1 and P22-5 (closed).
  • J
    Jeremy BurtonAug 12, 2025
    What to do if Emerson Industrial Equipment shows compressor short cycle alarm?
    • D
      danielfordAug 13, 2025
      If you're getting a compressor short cycle alarm with your Emerson Industrial Equipment, increase the proportional band a bit. Then, adjust the integration time to somewhere between 3 and 5 minutes. Keep an eye on how long the compressor runs; it needs to stay above 3 minutes to prevent short cycling.
  • B
    Bryan WilliamsAug 19, 2025
    How to fix if Emerson Industrial Equipment unit is too slow to activate cooling?
    • S
      Samuel WashingtonAug 19, 2025
      If your Emerson Industrial Equipment unit is activating cooling too slowly, try decreasing the proportional band slightly and monitor how it operates.
  • E
    emily66Oct 25, 2025
    What to do if modulating motors are not working on my Emerson Air Conditioner?
    • L
      Laura BallOct 25, 2025
      If you're experiencing issues with the modulating motors in your Emerson Air Conditioner, consider these potential causes and solutions: 1. **No 24 VAC power to motor:** Check the linkage for adjustment and ensure it is securely tightened on the valve. 2. **No signal from control:** Check the DC voltage on the printed circuit board in the motor. Terminal No. 1 is grounded, and No. 3 is positive. The DC voltage should vary from 0.8 to 2.0 VDC or above as the temperature control is varied below room temperature on a cooling valve or above room temperature on a heating valve. 3. **Motor not working:** Disconnect the wires on Terminal No. 1 and No. 3 from the motor (avoid shorting). With 24 VAC power from TR to TR, use a jumper wire to connect terminals 1 and 2 on the motor to drive it ope...

Summary

3.0 OPERATION

3.1 Single Unit Functions

Covers basic operational controls for individual cooling units.

3.2 Temperature Control

Explains how the system manages temperature setpoints and control types.

3.3 Tandem Compressors

Describes the operation and configuration of tandem compressor setups.

3.4 Temperature Control-Reheat

Covers how reheat functions are controlled for temperature regulation.

3.5 Humidity Control

Explains the system's humidity control types and operation.

3.6 Supply Control

Details how the system controls supply air temperature and compensation.

3.8 CANbus Connections Between the Liebert DSE, Liebert EconoPhase and Liebert MC

Explains the CANbus communication setup for system integration.

5.0 INSTALLING A LIEBERT ICOM UNIT-TO-UNIT NETWORK

7.0 USER MENU PARAMETERS

8.0 SERVICE MENU PARAMETERS

8.1 Service-Setpoints Menu Screens

Allows setting temperature and humidity-related parameters.

8.4 Service-Diagnostics; Service Mode Screens

Provides troubleshooting tools, alarm counters, and diagnostic features.

8.5 Service-Set Alarms Menu Screens

Modifies critical alarm thresholds, time delays, and event types.

8.7 Service-Sensor Calibration Menu Screens

Allows viewing and calibrating readings from connected sensors.

Emerson Liebert iCOM Specifications

General IconGeneral
CategoryComputer Hardware
ManufacturerEmerson
ModelLiebert iCOM
Power Requirements100-240 VAC, 50/60 Hz
DimensionsVaries by model
WeightVaries by model
TypeControl System
Communication ProtocolsBACnet, Modbus, SNMP
Communication PortsEthernet, RS-485
User InterfaceLCD Touchscreen
Operating Temperature0°C
Humidity Range5-95% RH, non-condensing