Loading...
Identifier VM_TORQUE_CURRENT
Description
Range applied to torque and torque producing current parameters. (Where this is used in Regen
mode it refers to the active current.)
Units %
Range of
[MIN]
-1000.0 to 0.0
Range of
[MAX]
0.0 to 1000.0
Select Motor 2 Parameters
(11.045)
VM_TORQUE_CURRENT[MAX]
0 VM_MOTOR1_CURRENT_LIMIT[MAX]
1 VM_MOTOR2_CURRENT_LIMIT[MAX]
VM_TORQUE_CURRENT[MIN] = -VM_TORQUE_CURRENT[MAX]
Identifier VM_TORQUE_CURRENT_UNIPOLAR
Description Unipolar version of VM_TORQUE_CURRENT
Units %
Range of [MIN] 0.0
Range of [MAX] 0.0 to 1000.0
VM_TORQUE_CURRENT_UNIPOLAR[MAX] = VM_TORQUE_CURRENT[MAX]
VM_TORQUE_CURRENT_UNIPOLAR[MIN] =0.0
Identifier VM_USER_CURRENT
Description Range applied to torque reference and percentage load parameters with one decimal place
Units %
Range of [MIN] -1000.0 to 0.0
Range of [MAX] 0.0 to 1000.0
VM_USER_CURRENT[MAX] = User Current Maximum Scaling (04.024)
VM_USER_CURRENT[MIN] = -VM_USER_CURRENT[MAX]
Identifier VM_USER_CURRENT_HIGH_RES
Description Range applied to torque reference and percentage load parameters with two decimal places
Units %
Range of [MIN] -1000.00 to 0.00
Range of [MAX] 0.00 to 1000.00
VM_USER_CURRENT_HIGH_RES[MAX] = User Current Maximum Scaling (04.024) with an additional decimal place
VM_USER_CURRENT_HIGH_RES[MIN] = -VM_USER_CURRENT_HIGH_RES[MAX]