EasyManua.ls Logo

Emerson Powerdrive F300 - Page 65

Emerson Powerdrive F300
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter 04.029 Enable Trip On Low Load
Short description Defines the action taken when low load is detected
Mode OpenLoop
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW
See Low Load Detection Level (04.027).
Parameter 04.036 Motor Protection Accumulator Power-up Value
Short description Defines the initial power-up value of the motor protection accumulator
Mode OpenLoop
Minimum 0 Maximum 2
Default 0 Units
Type 8 Bit User Save Update Rate Background write
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Power down
1 Zero
2 Real time
See Motor Thermal Time Constant 1 (04.015).
Parameter 04.037 Motor Thermal Time Constant 2
Short description Can be used to define an additional motor thermal time constant
Mode OpenLoop
Minimum 1.0 Maximum 3000.0
Default 89.0 Units s
Type 16 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 1
Coding RW
See Motor Thermal Time Constant 1 (04.015).
Parameter 04.038 Motor Thermal Time Constant 2 Scaling
Short description
Defines the ratio of the contribution to the motor protection accumulator value from each of the time
constants
Mode OpenLoop
Minimum 0 Maximum 100
Default 0 Units %
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW
See Motor Thermal Time Constant 1 (04.015).
Parameter 04.039 Rated Iron Losses As Percentage Of Losses
Short description Set to the rated iron losses of the motor as a percentage of the total losses for the motor
Mode OpenLoop
Minimum 0 Maximum 100
Default 0 Units %
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW
See Motor Thermal Time Constant 1 (04.015).