Menu 5 Single Line Descriptions − Motor Control
Mode: OpenLoop
Parameter Range Default Type
05.001 Output Frequency ±VM_SPEED_FREQ_REF Hz RO Num ND NC PT FI
05.002 Output Voltage ±VM_AC_VOLTAGE V RO Num ND NC PT FI
05.003 Output Power ±VM_POWER kW RO Num ND NC PT FI
05.004 Motor Rpm ±180000 rpm RO Num ND NC PT FI
05.005 D.c. Bus Voltage ±VM_DC_VOLTAGE V RO Num ND NC PT FI
05.006 Rated Frequency 0.0 to 550.0 Hz
50Hz: 50.0 Hz
60Hz: 60.0 Hz
RW Num US
05.007 Rated Current ±VM_RATED_CURRENT A 0.000 A RW Num RA US
05.008 Rated Speed 0 to 33000 rpm
50Hz: 1500 rpm
60Hz: 1800 rpm
RW Num US
05.009 Rated Voltage ±VM_AC_VOLTAGE_SET V
200V drive: 230 V
400V drive 50Hz: 400 V
400V drive 60Hz: 460 V
575V drive: 575 V
690V drive: 690 V
RW Num RA US
05.010 Rated Power Factor 0.000 to 1.000 0.850 RW Num RA US
05.011 Number Of Motor Poles Automatic (0) to 480 (240) Poles Automatic (0) Poles RW Txt US
05.012 Autotune None (0), Basic (1), Improved (2) None (0) RW Txt NC
05.013 Dynamic V To F Select Off (0) or On (1) On (1) RW Bit US
05.014 Openloop Control Mode
Ur S (0), Ur (1), Fixed (2), Ur Auto (3), Ur I (4),
Square (5)
Ur I (4) RW Txt US
05.015 Low Frequency Voltage Boost 0.0 to 25.0 % 3.0 % RW Num US
05.017 Stator Resistance 0.000000 to 1000.000000 Ω 0.000000 Ω RW Num RA US
05.018 Maximum Switching Frequency 0 to VM_SWITCHING_FREQUENCY kHz 3 (1) kHz RW Txt RA US
05.019 High Stability Space Vector Modulation Off (0) or On (1) Off (0) RW Bit US
05.020 Quasisquare Enable Off (0) or On (1) Off (0) RW Bit US
05.024 Transient Inductance 0.000 to 500.000 mH 0.000 mH RW Num RA US
05.025 Stator Inductance 0.00 to 5000.00 mH 0.00 mH RW Num RA US
05.027 Enable Slip Compensation Off (0) or On (1) On (1) RW Bit US
05.031 Voltage Controller Gain 1 to 30 1 RW Num US
05.035 Autoswitching Frequency Change
Enabled (0), Disabled (1),
No Ripple Detect (2)
Enabled (0) RW Txt US
05.036 Autoswitching Frequency Step Size 1 to 2 2 RW Num US
05.037 Switching Frequency 2 (0), 3 (1), 4 (2), 6 (3), 8 (4), 12 (5), 16 (6) kHz RO Txt ND NC PT
05.038 Minimum Switching Frequency 0 to VM_MIN_SWITCHING_FREQUENCY kHz 2 (0) kHz RW Txt US
05.039 Maximum Inverter Temperature Ripple 20 to 60 °C 60 °C RW Num US
05.040 Spin Start Boost 0.0 to 10.0 1.0 RW Num US
05.042 Reverse Output Phase Sequence Off (0) or On (1) Off (0) RW Bit US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr Character parameter Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP Slot, menu, parameter
Num Number parameter DE Destination ND
No
default value
RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS
Power-
down save
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00