CODE POSSIBLE CAUSE POSSIBLE SOLUTION
17
Carbon build-up in pump. Contact an authorized service center.
18
Detergent type oil being used in pump Drain oil and refill pump with ISO 100/SAE40, non-deter-
gent, premium air compressor oil.
19 Motor overload protection switch has tripped See Motor Overload under Features.
20
Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See
Extension Cords under Installation.
21
Loose electrical connections Contact an authorized service center.
22
Possible defective motor or starting capacitor Contact an authorized service center.
23
Paint spray on internal motor parts Contact an authorized service center. Do not operate the
compressor in the paint spray area. See flammable vapor
warning.
24
Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as
necessary. Reset circuit breaker. Do not use a fuse or
circuit breaker with higher rating than that specified
for your particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper
extension cord.
4. Disconnect the other electrical appliances from circuit
or operate the compressor on its own branch circuit.
25
Tank pressure exceeds pressure switch cut-in pressure Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
26
Pressure release valve on pressure switch has not
unloaded head pressure
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact an authorized service center.