6
Output No.: The output number defines the weld tool which will be
addressed based on the TMP connector configuration.
When indicating the output the following operation modes are to be differentiated:
Standard
operation
In standard operation (feeder - SKK/PK) the output no. must
be entered corresponding to the TMP connector configuration.
For example: "TMP-pin 1 - feeder 1 - SKK/PK no. 1".
SD2 operation
When using a 2-way stud divider "SD2" only output no. 1 is to
be addressed.
SD5 operation
When using a 5-way stud divider the output no. is to be
entered corresponding to the "SD5" configuration. For
example: "SD5 connector configuration 3 - SKK no. 3".
SD5 operation When using a 5-way stud divider the output no. is to be
entered corresponding to the "SD5" configuration. For
example: "SD5 connector configuration 3 - SKK no. 3".
Weld Program
No.
For each weld task a specific weld program should be
available which is to be addressed via the corresponding
program no. (1 - 127).
Enter a number between 1 and 5 for the weld output as well as between 1 and 127
for a weld program via the numerical keypad and confirm with or press
to exit the input mode.
Yes External program selection enabled.
No External program selection disabled.
Remark: if no external program selection is requested only
weld program 1 may be activated for the corresponding
output.
Weld diameter Selection of weld flange diameter.
Flange diameter Selection of flange diameter in a range from 2 mm - 8 mm
(step size: 1 mm).
SWB10 When welding T-studs with a length of 3,8 mm and a flange
diameter of 3 mm the TUCKER-name SWB10 is to be entered.
Workpiece
Gauge
Selection of sheet thickness of work surface: 0,8 mm, 1,2 mm,
2 mm or >2 mm.