EasyManua.ls Logo

emmeti XECO-2815QE User Manual

emmeti XECO-2815QE
64 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Air Conditioners
Serie:
XECO - XX15E - XX15XE - XX16XE
OUTDOOR UNITS
MANUALE INSTALLAZIONE ED ISTRUZIONI PER L’USOMANUALE INSTALLAZIONE ED ISTRUZIONI PER L’USO
ITIT
INSTALLATION MANUAL AND USING INSTRUCTIONSINSTALLATION MANUAL AND USING INSTRUCTIONS
GBGB
MANUAL INSTALACIÓN E INSTRUCCIONES PARA EL USO MANUAL INSTALACIÓN E INSTRUCCIONES PARA EL USO
ESES
MANUEL D’INSTALLATION ET INSTRUCTIONS D’USAGE MANUEL D’INSTALLATION ET INSTRUCTIONS D’USAGE
FRFR
Question and Answer IconNeed help?

Do you have a question about the emmeti XECO-2815QE and is the answer not in the manual?

emmeti XECO-2815QE Specifications

General IconGeneral
RefrigerantR410A
TypeSplit System
Heating Capacity28000 BTU/h
EER3.5
COP3.8
Energy Efficiency Ratio (EER)3.21 W/W
Coefficient of Performance (COP)3.8
Power Supply220-240V, 50Hz

Summary

2. WARNINGS

2.1 Attention and dangers

Highlights critical safety warnings and symbols to prevent hazards and misuse of the appliance.

3. IMPORTANT INFORMATION

3.5 Part of refrigerant safety table

Presents detailed safety information regarding the refrigerant R410A.

5. UNIT POSITION

5.2 Minimum functional distances of the external unit

Specifies required clearances around the external unit for proper airflow and function.

6. INSTALLATION OF THE INTERNAL UNIT

6.1 External unit installation

Instructions for installing the outdoor unit, including anti-vibration pads and stability.

6.3 Refrigerating circuit piping

Details the specifications and connection procedures for the refrigerant piping.

6.4 Electrical supply

Covers the requirements and procedures for electrical connections to the unit.

6.4.4 Connection to the outdoor unit terminal board

Step-by-step guide on connecting cables to the outdoor unit's terminal board.

7. LOAD AND SYSTEM TEST

7.1 Draining and filling the refrigerating circuit with R 410 A

Detailed procedure for draining and filling the refrigerant circuit, including safety precautions.

7.1.1 Procedura di vuoto e carica

Step-by-step vacuuming and charging procedure for the refrigeration circuit.

7.1.2 Precautions when adding refrigerant

Specific precautions to take when adding refrigerant, especially for R410A.

7.2 Test running

Instructions for performing initial start-up tests in cooling and heating modes.

9. MALFUNCTION

10. ELECTRIC SCHEMES

11. REFRIGERANT CIRCUITS

GUARANTEE CERTIFICATE