Dimension and Clearance
20
Electric Power Supply Requirements
Your range must be electrically grounded in accordance with local codes or, in the absence of local
codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes. A copy of this standard may be obtained from: National
Fire Protection Association, 1 Battery march Park, Quincy, Massachusetts 02269-9101.
The power supply must be the correct polarity. Reverse polarity will result in continuous sparking of
the electrodes, even after flame ignition. If there is any doubt as to whether the power supply has
the correct polarity or grounded, have it checked by a qualified electrician.
Use 120V, 60Hz, and properly grounded branch circuit protected by a 15-amp or 20-amp circuit
breaker or time delay fuse.