Page 1R-5086
INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
CAST IRON
DIRECT VENT FIREPLACE
MODEL
CIDV-30-7
EFFECTIVE DATE
AUGUST, 2000
FOR YOUR SAFETY: What to do if you smell
gas:
Do not touch any electrical switches
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier from a
neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
POUR VOTRE SÉCURITÉ: Que faire si vous
sentez une odeur de gaz:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le
bâtiment où vous vous trouvez.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury or loss of life.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency, or the gas
supplier.
AVERTISSEMENT: Une installation, un réglage,
une modification, un entretien ou une maintenance
incorrects peuvent entraîner des dommages
matériels, des lésions corporelles ou la perte de vies
humaines. Consulter le manuel des usagers fourn
avec ce générateur d'air chaud.
AVERTISSEMENT: Quiconque ne respecte pas à
la lettre les instructions dans le présent manuel
risque de déclencher un incendie ou une explosion
entraíant des dommages matériels, des lésions
corporelles ou la perte de vies humaines.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
Cet appareil peut être installé dans une maison
préfabriquée (mobile) déjà installée à demeure si
les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les
types de gaz indiqués sur la plaque signalétique. Ne
pas l'utiliser avec d'autres gaz sauf si un kit de
conversion certifié est installé.

Questions and Answers

  • S
    Shawn JacksonAug 6, 2025
    What to do if pilot is burning but no gas to burner on Empire Comfort Systems Indoor Fireplace?
    • J
      Jacqueline RichardsonAug 6, 2025
      If the pilot is burning but no gas is reaching the burner with the valve knob and on/off switch both in the 'ON' position, the issue might be with the 'On/Off' switch, wall switch, or wiring. Check the switch and wires for secure connections. You can use jumper wires across the terminal at the switch; if the burner ignites, the switch is defective and needs replacement. If the switch is okay, use jumper wires across the switch wires at the gas valve—if the burner then ignites, the wires are faulty or have bad connections. Another potential cause is a defective valve. With the valve knob and on/off switch set to 'ON,' use a millivolt meter at the thermopile terminals. If the meter reads greater than 100 M.V. but the burner still doesn't ignite, the gas valve needs replacing.
  • P
    pperezAug 10, 2025
    How to fix spark ignitor that will not light pilot on Empire Comfort Systems CIDV-30 Indoor Fireplace?
    • M
      Mary SullivanAug 10, 2025
      If the spark ignitor on your Empire Comfort Systems Indoor Fireplace fails to light the pilot after repeatedly pressing the piezo ignitor button, it could be due to a defective ignitor or a gas supply issue. First, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the ignitor. Also, ensure that the gas supply is adequate by checking remote shut-off valves from the fireplace; typically, there's a valve near the main gas line, and there may be multiple valves between the fireplace and the main line.
  • C
    Charlene MooreAug 14, 2025
    Why does my Empire Comfort Systems Indoor Fireplace pilot and main burner extinguish during operation?
    • R
      Rebecca WilsonAug 14, 2025
      If the pilot and main burner extinguish while in operation in your Empire Comfort Systems Indoor Fireplace, several factors could be at play. First, ensure that the LP (Propane) tank is not empty and refill it if necessary. Additionally, inspect the inner vent pipe for any leaks that may be allowing exhaust gases to re-enter the system. Check that the glass assembly is correctly installed and tighten the corners, as loose glass can cause gasket leaks. Finally, verify that the horizontal vent is properly pitched, with a downward slope no greater than 1/4 inch to prevent water entry.
  • B
    Bridget AndersonAug 19, 2025
    What to do if pilot will not stay lit on Empire Comfort Systems CIDV-30?
    • R
      Robert DaltonSep 12, 2025
      If the pilot on your Empire Comfort Systems Indoor Fireplace won't stay lit even after carefully following the lighting instructions, the thermocouple might be defective. Ensure the pilot flame makes contact with the thermocouple. Clean and adjust the pilot for maximum flame impingement. If the thermocouple is producing more than 15 millivolts, the valve may be faulty and needs replacement.
  • R
    Richard MooreAug 22, 2025
    How to stop glass sooting on Empire Comfort Systems CIDV-30 Indoor Fireplace?
    • S
      Sarah BenderAug 23, 2025
      If you notice the glass of your Empire Comfort Systems Indoor Fireplace sooting, it could be due to flame impingement on the logs or an improper air shutter adjustment. Adjust the log set to minimize flame contact. Additionally, adjust the air shutter to optimize the air-to-fuel mixture.
  • R
    Rebecca JacksonAug 27, 2025
    Why frequent pilot outage problem on Empire Comfort Systems CIDV-30 Indoor Fireplace?
    • W
      wrightjesseAug 27, 2025
      If you are experiencing frequent pilot outages with your Empire Comfort Systems Indoor Fireplace, it may be because the pilot flame is either too high or too low, or it's being blown out, causing the pilot safety to drop out. Ensure the pilot flame is clean and properly adjusted for maximum flame impingement on the thermocouple. Follow the lighting instructions carefully.
  • R
    Richard DavilaAug 31, 2025
    Why flame lifts off main burner on Empire Comfort Systems CIDV-30 Indoor Fireplace?
    • R
      Rhonda SmithSep 1, 2025
      If the flame lifts off the main burner of your Empire Comfort Systems Indoor Fireplace, it indicates that insufficient oxygen is being supplied. Check that the vent cap is properly installed and free of any obstructions. Also, ensure that all joints in the vent system are tight and without leaks.

Summary

General Safety and Operation

Gas Leak Detection and Response

Instructions on what to do if you smell gas, including actions to avoid and who to contact.

LP-Gas Safety Information

LP-Gas Warning Odor and Response

Explains the odorant in LP-gas as a warning signal and the immediate actions required during a leak.

Installation Requirements and Gas Supply

High Altitude and Gas Supply Guidelines

Instructions for high altitude installations and recommendations for gas supply piping.

Gas System Installation and Testing

Gas Supply Piping and Main Gas Cock

Recommendations for gas pipe diameter, connectors, and installing a new main gas cock.

Stove Casting Assembly Overview

Casting Assembly Stages and Instructions

Outlines the six stages of assembling the cast iron stove casing.

Detailed Stove Casting Assembly

Attaching Legs, Leg Pads, and Leveling Bolts

Step-by-step instructions for attaching the legs, leg pads, and leveling bolts to the casing.

Casing Front and Firebox Installation

Ignition System and Venting Basics

Venting Graph and Requirements

Using the Venting Graph for Horizontal Run

Guide on how to use the venting graph to determine allowable horizontal vent run based on vertical rise.

Venting Requirements and Limitations

Details minimum vertical rise, maximum horizontal run, and elbow limitations for venting.

Restrictor Plate Installation

Step-by-Step Restrictor Plate Installation

Detailed instructions for installing the restrictor plate in the vent system.

Venting Termination Clearances

Clearances for Building Configurations

Specifies termination clearances for various building configurations like corners, recesses, and balconies.

Vent Terminal Clearances

Vent System Installation and Support

Installing Vent Components and Sections

Instructions on how to install vent pipes, elbows, and termination kits, including component locking.

Firestop Installation Procedures

Installing Firestops in Walls and Ceilings

Step-by-step guide for installing firestops in walls and ceilings for vent systems.

Venting Termination Installation

Horizontal Vent Termination Steps

Instructions for attaching and securing the horizontal vent termination cap, including warnings.

Vertical Vent Termination and Roof Height

Guidance on vertical termination installation, roof hole sizing, and minimum vent height above the roof.

Venting Maintenance and Chase Installation

Appliance Maintenance and Log Installation

Glass Safety Warnings

Important warnings regarding the use of correct glass, avoiding breakage, and operating without the glass front.

Log Set Installation Procedure

Step-by-step instructions for removing and installing the ceramic log set inside the firebox.

Glass Panes and Pilot Flame

Gasket Replacement on Glass Panes

Detailed procedure for replacing the gasket on the glass panes of the appliance.

Pilot Flame Pattern Analysis

Illustrates correct and incorrect pilot flame patterns and their impact on operation.

Main Burner Flame, Cleaning, and Operation

Operating Modes and Accessory Connections

Explains the ON/OFF/REMOTE switch and connections for various accessories like thermostats and remotes.

Switch, Remote Control, and Operating Guidelines

Wiring ON;OFF;REMOTE Switch with Accessories

Details on wiring the ON/OFF/REMOTE switch to thermostats, wall switches, and remote receivers.

Appliance Lighting and Cleaning

Pilot Lighting and Shut-off Procedures

Step-by-Step Pilot Lighting Instructions

Detailed instructions for lighting the pilot using the gas control knob and piezo ignitor.

Troubleshooting Common Issues

Optional Blower Installation and Control

Empire Comfort Systems CIDV-30 Specifications

General IconGeneral
Fuel TypeNatural Gas or Liquid Propane
Vent TypeDirect Vent
Log MaterialCeramic Fiber
Burner MaterialStainless Steel
Ignition SystemElectronic
Warranty5-Year Limited
BTU30, 000 BTU

Related product manuals