INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
CAST IRON
UNVENTED
ROOM HEATER
MODELS
VFCM-25-3
VFCR-25-3
VFCT-25-3
WATER VAPOR: A BY-PR O D UCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 6.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation
air must be provided. Refer to page 6.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
EFFECTIVE DATE
AUGUST 2006
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.

Questions and Answers

  • E
    Eric JoyceAug 20, 2025
    What to do if Empire Comfort Systems VFCM-25-3 has spark but no ignition?
    • K
      Kevin TrujilloAug 20, 2025
      If your Empire Comfort Systems Gas Heater shows a spark at the ODS/pilot when the ignitor button is pressed, but there's no ignition, here are a few things to check: * Ensure the gas supply is turned on and the manual shutoff valve is open. * Confirm the gas control knob is in the PILOT position and pressed in. * If the heater was recently installed, there might be air in the gas lines. Continue holding down the control knob and repeat the igniting operation until the air is removed. * The ODS/pilot could be clogged, in which case you should clean or replace the ODS/pilot assembly. If none of these steps work, it may be necessary to replace the gas regulator or contact your local gas company for assistance.
  • H
    hmyersAug 25, 2025
    Why does my Empire Comfort Systems VFCM-25-3 smell?
    • L
      Laura JacksonAug 25, 2025
      If your Empire Comfort Systems Gas Heater produces an unwanted odor, it could be due to: * The heater burning vapors from paint, hair spray, glues, cleaners, chemicals, or new carpet. Open a window to ventilate the room and stop using odor-causing products while the heater is operating. * Low fuel. Refill the supply tank. * Gas leaks. Locate and correct any leaks.
  • L
    Lindsey ColemanAug 26, 2025
    What to do if Empire Comfort Systems VFCM-25-3 Gas Heater main burner won't light?
    • D
      Daniel LawrenceAug 27, 2025
      If the main burner of your Empire Comfort Systems Gas Heater does not light after the ODS/pilot is lit, the main burner orifice may be clogged. Try cleaning the main burner or replacing the main burner orifice. If that doesn't resolve the issue, contact your local gas company.
  • D
    daniellecruzAug 28, 2025
    Why does Empire Comfort Systems VFCM-25-3 Gas Heater smell like gas when running?
    • M
      murphyjasonAug 28, 2025
      If you notice a gas odor during combustion with your Empire Comfort Systems Gas Heater, it could be due to foreign matter between the logs and the main burner. Remove any foreign matter. Alternatively, there could be a gas leak. Locate and correct all leaks.
  • D
    Dana BanksAug 30, 2025
    Why does my Empire Comfort Systems VFCM-25-3 Gas Heater keep shutting off?
    • T
      Tina MullinsAug 30, 2025
      If your Empire Comfort Systems Gas Heater shuts off while in use and the ODS (Oxygen Depletion Sensor) is operating, try opening a window or door for ventilation. If the problem persists, clean the ODS/pilot. You may also need to contact your local gas company.
  • K
    Kelly RamirezSep 1, 2025
    How to fix no spark on Empire Comfort Systems VFCM-25-3?
    • M
      Matthew WrightSep 1, 2025
      If there is no spark at the ODS/pilot when the ignitor button is pressed on your Empire Comfort Systems Gas Heater, you can try the following: * Replace the ignitor. * Reconnect the ignitor cable. * Ensure the ignitor cable is free from being pinched by any metal or tubing and keep the ignitor cable dry. * Replace the ignitor cable or the piezo ignitor if necessary.
  • L
    Linda AllenSep 5, 2025
    Why does my Empire Comfort Systems Gas Heater smell like gas when off?
    • S
      Steven SantosSep 5, 2025
      If you smell gas even when the control knob of your Empire Comfort Systems Gas Heater is in the OFF position, it likely indicates a gas leak. Locate and correct all leaks. If the odor persists, the control valve may need to be replaced.
  • A
    Anthony SmithSep 7, 2025
    Why is there a delay when igniting my Empire Comfort Systems Gas Heater?
    • J
      Jennifer MooreSep 7, 2025
      If your Empire Comfort Systems Gas Heater has a delayed ignition of the main burner, the main burner orifice may be clogged. Try cleaning the main burner and the main burner orifice. If the issue persists, contact your local gas company.
  • J
    Jessica GriffinSep 9, 2025
    Why does my Empire Comfort Systems VFCM-25-3 whistle?
    • W
      willisjimmySep 9, 2025
      If your Empire Comfort Systems Gas Heater produces a whistling noise when the main burner is lit: * Turn the control knob to the LO position and let it warm up for a minute. * It could be due to air in the gas line. Operate the main burner until the air is removed from the line. Have the gas line checked by your local gas company. * Check for blocked air passageways on the heater. * Clean the main burner and main burner orifice or replace the main burner orifice.
  • S
    Samuel WardSep 12, 2025
    Why is the flame yellow on my Empire Comfort Systems Gas Heater?
    • R
      Ryan SimmonsSep 12, 2025
      If you observe a yellow flame in the front section of the main burner during combustion in your Empire Comfort Systems Gas Heater, check the main burner for dirt and debris and clean it. If the problem persists, the gas regulator may need to be replaced.

Empire Comfort Systems VFCM-25-3 Specifications

General IconGeneral
BrandEmpire Comfort Systems
ModelVFCM-25-3
CategoryGas Heater
LanguageEnglish

Related product manuals