Step 7: Connect the wire harness
If wiring to an empty (unused) breaker,
wire it directly to the breaker. Ampacity
rating of this breaker does not matter.
1.) Wiring to an empty breaker
If wiring to an in-use breaker, use the
splicing wires / wire nuts included with
the Vue for breakers rated up to 15A. Any
amapacity rating may be used if the
splicing wire gauge matches the existing
wire and meets applicable electric codes.
2.) Wiring to an in-use breaker
If the wire harness is wired to an AFCI /
GFCI breaker, the black wire needs to be
wired to the hot side and the white to the
neutral on this breaker. The white is not
wired to the neutral bus.
3.) Wiring to a AFCI / GFCI breaker
AFCI /
GFCI
The wire harness is wired to one or more
breakers in the electric panel.