EasyManua.ls Logo

EMX Industries MVP D-TEK - User Manual

Default Icon
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EMX Industries, Inc. Tech support: 216-834-0761 1/7
MVP D-TEK_Rev2.0_081319 technical@emxinc.com
MVP D-TEK
Multi-Voltage Vehicle Loop Detector
Instruction Manual
The MVP D-TEK vehicle loop detector allows for detection of metallic objects entering the field formed
around an induction loop. This detector automatically adjusts to input power from 12 VDC up to 240 VAC
which eliminates the installer’s need to match available power to an appropriately rated vehicle detector.
The MVP D-TEK is made from anodized aluminum and all switches have gold plated contacts that are sealed
for protection. It features full loop diagnostic with frequency counter, 10 sensitivity settings, delay mode,
extend mode, fail safe/fail secure mode, automatic sensitivity boost, pulse and presence operating modes
and two output relays.
Cautions and Warnings
This product is an accessory or part of a system. Install the MVP D-TEK according to
instructions from the gate or door operator manufacturer. Comply with all applicable
codes and safety regulations.
MVP D-TEK Multi-voltage vehicle loop detector (included)
HAR-11 11 position harness, 3of wire
LD-11 11 pin DIN rail socket, black, wide base
LD-11B 11 pin DIN rail socket, black, narrow base
PR-XX Lite preformed loop (XX specify size)
TSTL Test loop, troubleshooting tool
Specifications
Power
12-60 VDC or 12-240 VAC (48-62 Hz)
Draw Current
19.2 mA
Loop Frequency
3 settings (low, medium, high)
Loop Induction
20-2000 μH (Q factor ≥ 5)
Surge Protection
MOV, neon and silicon protection devices
Relay Contact Rating
2 DPST 1A @ 30 VDC
Operating Temperature
-40º to 180ºF (-40º to 82ºC)
Housing Material
Anodized aluminum
Connector
11 pin male connector (JEDEC B11-88)
compatible with DIN rail mount socket or wire harness
Dimensions (L x W x H)
3.25” (83 mm) x 2.56” (40 mm) x 3.65” (90 mm)
Ordering Information
TM

Questions and Answers

  • S
    Stephen RossJul 28, 2025
    Why does my EMX Industries MVP D-TEK Security Sensors detector detect intermittently when no vehicle is on the loop?
    • T
      Thomas YoderJul 28, 2025
      Intermittent detection by your EMX Industries Security Sensors, even when no vehicle is present, can stem from several causes: * A faulty loop. * Poorly crimped or loose connections. * Cross-talk between multiple loop detectors. * The loop not being securely installed, leading to movement within the pavement. To resolve this: 1. Perform a megger test from the loop lead to the ground, ensuring it exceeds 100 megaohms. 2. Inspect loop connections at the terminals. 3. Confirm splices are correctly soldered and moisture-sealed. 4. Set multiple loops to different frequencies. 5. Ensure the loop is securely installed in the pavement and that the site's condition prevents loop wire movement.
  • B
    Bryan FoxAug 2, 2025
    What to do if the red LED is constantly on (stuck in detection mode) on my EMX Industries MVP D-TEK?
    • H
      Hannah MaysAug 3, 2025
      If the red LED on your EMX Industries Security Sensors is constantly illuminated, indicating it's stuck in detection mode, it could be due to a faulty loop or a poorly crimped/loose connection. To address this: * Perform a megger test from the loop lead to ground, ensuring the reading exceeds 100 megaohms. * Check the loop connections at the terminals. * Verify that all splices are properly soldered and sealed against moisture.
  • R
    Robin NealAug 8, 2025
    How to fix a fast flashing green LED on EMX Industries MVP D-TEK Security Sensors?
    • V
      vsmithAug 8, 2025
      A fast flashing green LED on your EMX Industries Security Sensors indicates a shorted or disconnected loop wire. Here’s how to troubleshoot: * Check the loop resistance using a multimeter; it should read between 0.5 ohms and 5 ohms. If the reading falls outside this range, replace the loop. The reading should be steady. * Inspect loop connections to the terminals. * Momentarily flip the RESET switch down.
  • K
    Kyle MooreAug 14, 2025
    What does it mean if the green LED is slowly flashing on my EMX Industries MVP D-TEK?
    • G
      grantwilliamAug 14, 2025
      A slow flashing green LED on your EMX Industries Security Sensors typically means the loop wire was previously shorted or open. To resolve this, check the loop resistance with a multimeter to ensure it reads between 0.5 ohms and 5 ohms. If the reading is outside this range, replace the loop, ensuring the reading is steady. Then, momentarily flip the RESET switch down.
  • R
    Ronald WilliamsAug 20, 2025
    How to troubleshoot a green LED that is not on for EMX Industries Security Sensors?
    • K
      Kimberly GarciaAug 20, 2025
      If the green LED on your EMX Industries Security Sensors is not lit, the most likely cause is a lack of power. Check the power supplied to the MVP D-TEK on pins 1 (white wire) and 2 (black wire). The voltage should measure between 12-240 VDC/AC.

Summary

Cautions and Warnings

Specifications

Ordering Information

Wiring Connections

Settings & Display

Extend Detect

Configure detection extension time using DIP switches 7 and 8.

Automatic Sensitivity Boost

Adjust sensitivity to maximum during detection for high-bed vehicles.

Filter Mode

Input a momentary delay to verify vehicle presence before activation.

Fail Safe;Fail Secure

Configure loop failure behavior for presence output and state changes.

Presence Mode

Set output to reset after 4 minutes or remain active.

Relay 2 Pulse Mode

Determine when Relay 2 pulses based on vehicle entry or exit.

Relay 2 Pulse;Presence Mode

Assign Relay 2 outputs to Presence or Pulse mode via DIP switch 1.

Sensitivity Setting

Adjust detection level using a 10-position rotary switch from 0 to 9.

Device Indicators

LED Indicators

Describes the function and states of the Power Green LED and Detect Red LED.

Control Switches

Frequency Counter;Reset Switch

Calibrates detector, checks operating frequency by counting flashes.

Frequency Switch

Assigns loop operation frequency to prevent crosstalk in multi-loop installations.

Loop Installation

New Slab Pour Installation

Describes loop installation in new concrete slabs using PVC pipe for stabilization.

Saw Cut Installation

Details cutting existing surfaces to install loop wire and sealing the cut.

Asphalt Resurfacing Installation

Explains loop installation when resurfacing asphalt with a saw cut and sand.

Gravel or Soil Installation

Outlines installation in gravel or soil by digging a trench and filling with sand.

General Installation Guidelines

Provides recommendations for preformed loops, power sources, and wire twisting.

Installation Steps

Configure DIP Switches

Set DIP switches according to preferences, referencing the Settings & Display section.

Connect Power Supply

Connect the 11-pin socket/harness to the detector and power supply pins 1 & 2.

Connect Loop Wires

Connect the loop wires to pins 7 and 8 (gray and brown wire).

Connect Operator Wires

Connect operator wires to the socket/harness per monitoring methods and manufacturer.

Adjust Sensitivity

Set sensitivity level and calibrate detector by flipping the RESET switch.

Test Frequency;Crosstalk

Perform frequency count to confirm different operating frequencies for multiple loops.

Calibrate Detector

Momentarily flip the RESET switch down to calibrate the MVP D-TEK to the loop.

Troubleshooting

Green LED Issues

Addresses issues with the Green LED not being on or flashing fast/slow.

Red LED Issues

Addresses the Red LED being constantly on (stuck in detection mode).

Intermittent Detection Issues

Addresses intermittent detection when no vehicle is present on the loop.

Warranty Information

EMX Industries MVP D-TEK Specifications

General IconGeneral
TechnologyDual-technology (PIR + Microwave)
Detection MethodPassive Infrared (PIR) and Microwave
Power Source12-24 VDC/VAC
Detection TechnologyDual-technology (PIR + Microwave)
Detection RangeUp to 15 m
Field of View90°
Operating Voltage12-24 VDC/VAC
Current Draw25 mA @ 12 VDC
Tamper SwitchYes
Alarm OutputForm C relay, 28 VDC/125 VAC, 1.0 A max