EasyManua.ls Logo

ENDA EDP2041 - User Manual

ENDA EDP2041
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SET
SET
EDP2041
ENDA
DIGITAL POTENTIOMETER
TX
RX
AOUT
1
1- Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........10-30V DC
8-24V AC
2- Modbus Selection
RS.........RS-485 Modbus Included
Blank.....N/A
2
35x77mm sized.
4 digits display.
Easy to use by front panel keypad.
Communication via RS-485 Modbus protocol or synchronous running between
two or more potentiomers (Optional).
Preset value can be adjusted from external buttons.
Display scale can be adjusted between -1999 and up to 9999.
Decimal point can be adjusted between 1. and 3. digits.
0-10V,0-20 mA a and 4-20mA output with adjustable minimum and maximum values.
‘Soft on’ and ‘soft off’ properties can be selected.
Parameter access protection on 3 levels.
CE marked according to European Norms.
OUTPUT
0-10V output
Accuracy :%0.1 Resolution : 1mV
Fluctuation : Maximum 30mV
Rise time from 0 to 10V is maximum 300ms
Digitally adjusted maximum 10mA, max. 10V potentiometer output.
ENDA EDP2041 DIGITAL POTENTIOMETER
Read this document carefully before using this device. The guarantee will be expired by
d a m a g e s i f y o u d o n ' t a t t e n d t o t h e d i r e c t i o n s i n t h e u s e r m a n u a l . A l s o w e d o n ' t
accept any compensations for personal injury, material damage or capital disadvantages.
Thank you for choosing ENDA EDP2041 potentiometer.
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
Ambient/storage temperature
Max. relative humidity
0 ... +50 °C/-25 ... +70°C (without icing)
Rated pollution degree
TECHNICAL SPECIFICATIONS
According to EN 60529 Front panel : IP65
Rear panel : IP20
Supply
230V AC +10% -20%, 50/60Hz or 24V AC ±10% 50/60Hz or optional 10-30V DC / 8-24V AC ±10% SMPS
Power consumption
Max. 7VA
2.5mm² Screw Connections
Wiring
Date retention
EMC
Safety requirements
EN 61326-1: 2013 (Performance criterion B for the EMC standards)
EEPROM (Min. 10 years)
EN 61010-1: 2012 (pollution degree 2, overvoltage category II, measurement category I)
ELECTRICAL CHARACTERISTICS
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
W77xH35xD71mm
Weight
Approx. 350g (after packing)
Enclosure material
Self extinguishing plastics
Order Code : EDP2041 -
INPUTS
Upwards input (UP)
Contact input or max. 24VDC logic input (active low)
Downwards input (DOWN)
Contact input or max. 24VDC logic input (active low)
OUTPUT
0-20mA output
Accuracy: %0.1 Resolution : 2µA
Fluctuation : Maximum 60µA
Rise time from 0 to 20mA is maximum 300ms
Digitally adjusted maximum 12V, max.20 mA potentiometer output.
80% Relative humidity for temperatures up to 31 % °C, decreasing linearly to 50% at 40°C.
KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and
DO NOT USE the device in similar hazardous locations.
Avoid any liquid contact while the device is switched on.
DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.
Up to date: 15.09.2021, modification reserved and can be change any time previous notice !
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
1. / 4
EDP2041-EN-15092021
english

Other manuals for ENDA EDP2041

Question and Answer IconNeed help?

Do you have a question about the ENDA EDP2041 and is the answer not in the manual?

Summary

TECHNICAL SPECIFICATIONS

Environmental Conditions

Specifies ambient/storage temperature, humidity, pollution degree, and height limits.

Electrical Characteristics

Details supply voltage, power consumption, wiring, data retention, EMC, and safety requirements.

Inputs

Describes contact or logic inputs for UP and DOWN functions.

Output

Details 0-10V and 0-20mA output specifications including accuracy and rise time.

Housing

Covers housing type, dimensions, weight, material, and cleaning instructions.

DIMENSIONS AND MOUNTING

Panel Cut-out

Provides the required panel cutout dimensions for flush mounting.

CONNECTION DIAGRAMS

General Connection Notes

Emphasizes qualified staff, electrical safety, and environmental protection during installation.

Synchronized Operating Connection

Explains setting up multiple potentiometers in master-slave configurations for synchronized control.

OPERATING MODES AND PARAMETERS

Running Mode vs. Programming Mode

Differentiates between the operational states of running and programming modes.

Parameter Adjustment Method

Details the procedure for adjusting parameters using the keypad and external buttons.

Output Diagrams

Visual representations of output behavior based on parameter settings.

MODBUS PROTOCOL ADDRESS MAP

Memory Map for Holding Registers

Lists parameters, their addresses, data types, and read/write permissions.

Memory Map for Coils and Discrete Inputs

Details memory maps for coils and discrete inputs with parameter names.

Modbus Error Messages

Explains Modbus error types, codes, meanings, and provides message examples.

Summary

TECHNICAL SPECIFICATIONS

Environmental Conditions

Specifies ambient/storage temperature, humidity, pollution degree, and height limits.

Electrical Characteristics

Details supply voltage, power consumption, wiring, data retention, EMC, and safety requirements.

Inputs

Describes contact or logic inputs for UP and DOWN functions.

Output

Details 0-10V and 0-20mA output specifications including accuracy and rise time.

Housing

Covers housing type, dimensions, weight, material, and cleaning instructions.

DIMENSIONS AND MOUNTING

Panel Cut-out

Provides the required panel cutout dimensions for flush mounting.

CONNECTION DIAGRAMS

General Connection Notes

Emphasizes qualified staff, electrical safety, and environmental protection during installation.

Synchronized Operating Connection

Explains setting up multiple potentiometers in master-slave configurations for synchronized control.

OPERATING MODES AND PARAMETERS

Running Mode vs. Programming Mode

Differentiates between the operational states of running and programming modes.

Parameter Adjustment Method

Details the procedure for adjusting parameters using the keypad and external buttons.

Output Diagrams

Visual representations of output behavior based on parameter settings.

MODBUS PROTOCOL ADDRESS MAP

Memory Map for Holding Registers

Lists parameters, their addresses, data types, and read/write permissions.

Memory Map for Coils and Discrete Inputs

Details memory maps for coils and discrete inputs with parameter names.

Modbus Error Messages

Explains Modbus error types, codes, meanings, and provides message examples.

Overview

The ENDA EDP2041 Digital Potentiometer is a versatile and user-friendly device designed for precise control and adjustment in various industrial applications. This potentiometer offers a range of functions and features that make it an essential component for systems requiring accurate output control and communication capabilities.

Function Description

The core function of the EDP2041 is to provide a digitally adjustable potentiometer output, allowing users to set and control values with high precision. It features a 4-digit display that shows the adjusted potentiometer value in "Running Mode" and can also display parameter names, values, or units in "Programming Mode." The device supports various output types, including 0-10V, 0-20mA, and 4-20mA, with adjustable minimum and maximum values. This flexibility allows it to integrate seamlessly into diverse control systems.

One of the key functionalities is its ability to operate in a synchronized manner with multiple potentiometers. Through the RS-485 Modbus protocol, the EDP2041 can act as a master potentiometer, controlling up to 127 slave potentiometers. In this setup, the output settings of slave potentiometers change proportionally to the master's settings, ensuring coordinated control across a network of devices. This feature is particularly useful in applications requiring distributed control or synchronized adjustments.

The device also incorporates "soft on" and "soft off" properties, which allow for gradual increases or decreases in output voltage or current. This smooth transition helps prevent sudden changes that could impact system stability or damage sensitive equipment. Users can configure the increasing and decreasing times for the output, providing fine-tuned control over the ramp-up and ramp-down processes.

Parameter access protection is a crucial security feature, offering three levels of protection for the device's settings. This ensures that only authorized personnel can modify critical parameters, preventing accidental or unauthorized changes that could compromise system operation.

Usage Features

The EDP2041 is designed for ease of use, featuring a front panel keypad for intuitive operation. The keypad includes increment and decrement keys, which are used for adjusting values in "Running Mode" and for parameter selection and value modification in "Programming Mode." A dedicated SET key facilitates entering and exiting different modes, as well as confirming parameter changes.

The digital display is a clear, 12.5 mm, 4-digit, 7-segment red LED display, ensuring excellent visibility of values and parameters. Users can adjust the display scale between -1999 and 9999, and the decimal point can be set between 1 and 3 digits, providing flexibility for various measurement ranges and precision requirements.

Preset value adjustment is a significant feature, allowing users to quickly set a desired output value. In "Running Mode," pressing a key enters the preset setup mode, where the preset value can be adjusted using the increment and decrement keys. This can also be done via external buttons, which are disabled in "Programming Mode" to maintain control integrity.

The device's communication capabilities via RS-485 Modbus protocol enable remote control and monitoring. This is particularly beneficial for systems where the potentiometer needs to be integrated into a larger control network or managed from a central location. The baud rate for RS-485 connection is adjustable, supporting various communication speeds.

The EDP2041 is suitable for flush-panel mounting according to DIN 43 700, making it easy to integrate into control panels. The compact dimensions and robust enclosure material, made of self-extinguishing plastics, ensure durability and safety in industrial environments.

Maintenance Features

While the document does not explicitly detail maintenance features, several aspects of the EDP2041's design contribute to its reliability and ease of upkeep. The EEPROM memory ensures data retention for a minimum of 10 years, meaning that configured parameters are preserved even in the event of power loss, reducing the need for frequent re-configuration.

The device's compliance with European Norms, including CE marking and adherence to EMC and safety requirements (EN 61326-1: 2013 and EN 61010-1: 2012), indicates a high standard of quality and reliability. These certifications suggest that the device is built to withstand typical industrial conditions and operate safely.

Installation instructions emphasize the importance of proper electrical connections by qualified staff and protection against humidity, vibrations, and severe soiling. These guidelines, if followed, contribute significantly to the device's longevity and stable operation, minimizing potential issues that would require maintenance. The warning to avoid corrosive, volatile, and flammable gases or liquids, and not to use abrasive cleaning agents, highlights the need for appropriate environmental conditions and cleaning practices to preserve the device's integrity.

In case of errors, the Modbus protocol includes error messages for communication and operating errors. These messages, such as "ILLEGAL FUNCTION," "ILLEGAL DATA ADDRESS," and "ILLEGAL DATA VALUE," help in diagnosing issues within the Modbus network, facilitating quicker troubleshooting and resolution.

Overall, the ENDA EDP2041 Digital Potentiometer is designed for reliable, precise, and secure operation, with features that support both standalone and networked control applications, while also considering practical aspects of installation and long-term use.

ENDA EDP2041 Specifications

General IconGeneral
Frequency50/60Hz
Operating Temperature0 to 50°C
Input TypeThermocouple, Resistance Thermometer
MountingPanel Mount
Supply Voltage230V AC
DisplayLED
Thermocouple InputJ, K, T, R, S, B, N
Resistance Thermometer InputPt100
Control OutputRelay or SSR driver
Relay Output250V AC
Protection ClassIP65
Measurement RangeDepends on sensor type
Resolution1 °C
Operating HumidityMax. 90% RH (non-condensing)
Power Supply230V AC

Related product manuals