TECHNICAL SPECIFICATIONS
Supply
230V AC +10 -20 , 50/60Hz or 24% % V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz± ±
Power consumption
Max 4VA
2.5mm² screw-terminal connections
±1%
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 ( )pollution degree 2, overvoltage category II
START INPUT
Input type
Control with mechanical contact.
Min. = 100ms, Max. =
On and Off times for input pulses
OUTPUT
ELEKTRÝKSEL ÖZELLÝKLER
OUT
Relay: 250V AC, 8A ( ), NO+NCfor resistive load
Mechanical 30.000.000 operation; Electrical 100.000 operation
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
2000mMax.
80% up to 31°C decreasing linearly 50% at 40°C.
Ambient/storage temperature
Max. Relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Selectable 99:59 min. or hour.
1 sec.
Rated pollution degree
According to EN 60529 Front panel : IP6
Rear panel : Ip20
5
Do not use the device in locations subject to corrosive and flammable gases.
HOUSING
Housing type
Suitable for flush-panel mounting
Dimensions
W77xH35xD71mm
Weight
Approx. 198g (after packing)
Enclosure material
Self extinguishing plastics
ThankyouforchoosingENDA ETM1411digitaltimer.
* 35 x 77mm sized.
* Single contact output for timing control.
* External start input.
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 mins.
0:01 .... 99:59 hrs.
* Decrease and increace step of time can be adjusted.
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be
adjusted.
* CE marked according to European Norms.
Connection Diagram
ENDA ETM 411isintendedforinstallationincontrolpanels.Makesurethatthedeviceis
usedonlyforintendedpurpose. Theshieldingmustbegroundedontheinstrumentside.
Duringaninstallation,allofthecablesthatareconnectedtothedevicemustbefreeof
electricalpower. Thedevicemustbeprotectedagainstinadmissiblehumidity,vibrations,
severesoilingandmakesurethattheoperationtemperatureisnotexceeded. Allinputand
outputlinesthatarenotconnectedtothesupplynetworkmustbelaidoutasshieldedand
twistedcables. Thesecablesshouldnotbeclosetothepowercablesorcomponents. The
installationandelectricalconnectionsmustbecarriedoutbyaqualifiedstaffandmustbe
accordingtotherelevantlocallyapplicableregulations.
1
Panel cut-out
Dimensions
Note:
1)Panelthickness
shouldbemaximum
7mm.
2)Ifthereisno60mm
freespaceattheback
sideofthedevice,it
wouldbedifficultto
removeitfromthepanel.
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
34mm
70mm
8mm
85mm
71mm
29mm
Flush mounting
clamp
Flush mounting
clamp
Depth
Rubber
gasket
Panel
Forremovingmountingclamps:
Pushouttheflush-mounting
clampindirection asshown
inthefigurebelow. Then,pull
outtheclampindirection
1
2.
2
1
While cleaning the device, solvents (thinner, benzine, acid etc.) or must not be used.corrosive materials
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-230VAC
DIGITAL TIMER
START
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1)
2)
Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
ENDA ETM1411 DIGITAL TIMER
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
MIN
HOUR
4
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Order Code : ETM1411-
1
Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
HOUR
MIN
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-230VAC
DIGITAL TIMER
START
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
START
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-24
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
24V AC/DC ±10%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
SURAN Industrieelektronik
D-72160Horba.N.
DettingerStr.9 Tel.:+49(0)7451/625617E-mail:info@suran-elektronik.de
Fax:+49(0)7451/6250650Internet:www.suran-elektronik.de
1./2ETM1411-E
uptodate:01022014,modificationreservedandcanbechangeanytimepreviousnotice!