TECHNICAL SPECIFICATIONS
Supply
230V AC +10 -20 , 50/60Hz or 24% % V AC/DC 10%, 50/60Hz or 12V AC/DC 10%, 50/60Hz± ±
Power consumption
Max 4VA
2.5mm² screw-terminal connections
±1%
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity
Time Accuracy
Indicator
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 ( )pollution degree 2, overvoltage category II
START INPUT
Input type
Control with mechanical contact.
Min. = 100ms, Max. =
On and Off times for input pulses
OUTPUT
ELEKTRÝKSEL ÖZELLÝKLER
OUT
Relay: 250V AC, 8A ( ), NO+NCfor resistive load
Mechanical 30.000.000 operation; Electrical 100.000 operation
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
2000mMax.
80% up to 31°C decreasing linearly 50% at 40°C.
Ambient/storage temperature
Max. Relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Selectable 99:59 min. or hour.
1 sec.
Rated pollution degree
According to EN 60529 Front panel : IP6
Rear panel : Ip20
5
Do not use the device in locations subject to corrosive and flammable gases.
HOUSING
Housing type
Suitable for flush-panel mounting
Dimensions
W77xH35xD71mm
Weight
Approx. 198g (after packing)
Enclosure material
Self extinguishing plastics
ThankyouforchoosingENDA ETM1411digitaltimer.
* 35 x 77mm sized.
* Single contact output for timing control.
* External start input.
* Display can be adjusted to show min. or sec.
* Scale ;
0:01 .... 99:59 mins.
0:01 .... 99:59 hrs.
* Decrease and increace step of time can be adjusted.
* Start and stop possibility by front panel.
* 16 different warning tones.
* Upper and lower limits of the setpoint can be
adjusted.
* CE marked according to European Norms.
Connection Diagram
ENDA ETM 411isintendedforinstallationincontrolpanels.Makesurethatthedeviceis
usedonlyforintendedpurpose. Theshieldingmustbegroundedontheinstrumentside.
Duringaninstallation,allofthecablesthatareconnectedtothedevicemustbefreeof
electricalpower. Thedevicemustbeprotectedagainstinadmissiblehumidity,vibrations,
severesoilingandmakesurethattheoperationtemperatureisnotexceeded. Allinputand
outputlinesthatarenotconnectedtothesupplynetworkmustbelaidoutasshieldedand
twistedcables. Thesecablesshouldnotbeclosetothepowercablesorcomponents. The
installationandelectricalconnectionsmustbecarriedoutbyaqualifiedstaffandmustbe
accordingtotherelevantlocallyapplicableregulations.
1
Panel cut-out
Dimensions
Note:
1)Panelthickness
shouldbemaximum
7mm.
2)Ifthereisno60mm
freespaceattheback
sideofthedevice,it
wouldbedifficultto
removeitfromthepanel.
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
34mm
70mm
8mm
85mm
71mm
29mm
Flush mounting
clamp
Flush mounting
clamp
Depth
Rubber
gasket
Panel
Forremovingmountingclamps:
Pushouttheflush-mounting
clampindirection asshown
inthefigurebelow. Then,pull
outtheclampindirection
1
2.
2
1
While cleaning the device, solvents (thinner, benzine, acid etc.) or must not be used.corrosive materials
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-230VAC
DIGITAL TIMER
START
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1)
2)
Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
In accordance with the safety regulations, the power
supply switch shall bring the identification of
the relevant instrument and it should be easily accessible
by the operator.
ENDA ETM1411 DIGITAL TIMER
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
MIN
HOUR
4
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Order Code : ETM1411-
1
Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
SET
START
STOP
ETM1411
DIGITAL TIMER
ENDA
OUT
HOUR
MIN
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-230VAC
DIGITAL TIMER
START
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
START
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ETM1411-24
DIGITAL TIMER
ENDA INDUSTRIAL ELECTRONICS
24V AC/DC ±10%
50/60Hz 4VA
OUT
250V AC 8A
RESISTIVE LOAD
SURAN Industrieelektronik
D-72160Horba.N.
DettingerStr.9 Tel.:+49(0)7451/625617E-mail:info@suran-elektronik.de
Fax:+49(0)7451/6250650Internet:www.suran-elektronik.de
1./2ETM1411-E
uptodate:01022014,modificationreservedandcanbechangeanytimepreviousnotice!
Question and Answer IconNeed help?

Do you have a question about the ENDA ETM1411 Series and is the answer not in the manual?

Summary

ENDA ETM1411 Digital Timer Overview

Product Features

Highlights key features like size, output type, input, adjustable display, scale, and warning tones.

Technical Specifications

Environmental and Electrical Conditions

Details ambient/storage conditions, humidity, pollution degree, supply voltage, power consumption, and wiring.

Timer Functionality and Output

Covers scale selection, time accuracy, indicator type, EMC compliance, safety requirements, and output relay specs.

Input and Housing Details

Specifies start input type, pulse times, housing type, dimensions, weight, and enclosure material.

Installation and Connection

Connection Diagram and Wiring

Provides a visual guide for connecting the device, including supply voltage and terminal assignments.

Power Supply and Safety Notes

Details power supply connection, fuse requirements, cable size, and essential safety instructions for installation.

Operation and Control

Run Mode Operations

Explains timer operation in run mode, including button functions for time adjustment and start/stop.

Programming Mode Parameters

Details navigation to programming mode and key parameters like setpoint limits, time units, and output selection.

Control Diagrams

Illustrates control logic diagrams for external start input and start/stop key operations.

Overview

The ENDA ETM1411 is a digital timer designed for installation in control panels, offering precise timing control with a single contact output. It is a compact device, measuring 35 x 77mm, and is CE marked according to European Norms, ensuring compliance with safety and quality standards.

Function Description

The ETM1411 functions as a digital timer with a wide range of adjustable settings. It features an external start input, allowing for remote activation. The display can be configured to show time in either minutes or seconds, with a range from 0:01 to 99:59 for both minutes and hours. The device allows for both increasing and decreasing the set time, with an adjustable step. Users can start and stop the timer directly from the front panel. Additionally, it offers 16 different warning tones and allows for the adjustment of upper and lower limits for the setpoint.

The timer operates in two main modes: Run Mode and Programming Mode. In Run Mode, the display shows the current time value, parameter value, or name. The START key, when held for one second, initiates the timer and voiced warning. Holding it for a few seconds accelerates the change rate. The STOP key, when held for one second, stops the timer and voiced warning (if Str.t. = EYP.1 mode is selected, the timer and voiced warning can be stopped if the external start input is off). Holding the STOP key for a few seconds also accelerates the change rate. The SET key is used to adjust the setpoint value in Run Mode and the selected parameter in Programming Mode. When pressed, the TIMER set value flashes, and it can be adjusted using the START and STOP keys with the step defined by in.de.

Programming Mode is accessed by pressing and holding the SET key for 3 seconds. Within Programming Mode, various parameters can be configured:

  • LE.ST (Lower Limit of Setpoint): Adjustable between 0.01 and E.UPL.
  • EUPL (Upper Limit of Setpoint): Adjustable between t.LoL and 99.59.
  • in.de (Increase or Decrease Step): Adjusts the step of the setpoint, between 1 and 30.
  • Lt.c (Selection of Time Unit): Allows selection between minutes (nin) or hours (Hour). If nin is selected, the time can be adjusted up to 99:59 minutes. If Hour is selected, the time can be adjusted up to 99:59 hours.
  • Str.t. (Selection of Start Type): Defines how the timer starts and stops using external start input and start/stop keys. Four different selection types are available, detailed in the control diagram.
  • Out.t (Selection of Relay Output): If EYP.0 is selected, the timer runs by start, and the relay contact shuts. When the time is over, the relay contact opens. If EYP.1 is selected, the timer runs by start, and when the time is over, the relay contact shuts.
  • Sond. (Selection of Buzzer Sound): Offers 16 different sounds. Selecting 0 cancels the warning tone.
  • S.Cod. (Access Code for Security Menu): This parameter should be 411.
  • A-t.S. (Access Code for Timer Set Menu): none makes the menu invisible. P.YES makes parameters of the menu changeable. P.no makes parameters of the menu only visible.
  • A-t.c. (Access Code for Timer Configuration Menu): none makes the menu invisible. P.YES makes parameters of the menu changeable. P.no makes parameters of the menu only visible.

Important Technical Specifications

Environmental Conditions:

  • Ambient/storage temperature: 0 ... +50°C (operating) / -25 ... +70°C (storage), without icing.
  • Max. Relative humidity: 80% up to 31°C, decreasing linearly to 50% at 40°C.
  • Rated pollution degree: According to EN 60529, with a front panel rating of IP65 and a rear panel rating of IP20.
  • Height: Max. 2000m.
  • Note: The device should not be used in locations subject to corrosive and flammable gases.

Electrical Specifications:

  • Supply: 230V AC +10% -20%, 50/60Hz; or 24V AC/DC ±10%, 50/60Hz; or 12V AC/DC ±10%, 50/60Hz.
  • Power consumption: Max 4VA.
  • Wiring: 2.5mm² screw-terminal connections.
  • Scale: Selectable 99:59 min. or hour.
  • Sensitivity: 1 sec.
  • Time Accuracy: ±1%.
  • Indicator: 4 digits, 12.5mm, 7 segment yellow LED.
  • EMC: EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. The device is designed to operate in a controlled electromagnetic environment).
  • Safety requirements: EN 61010-1: 2001 (pollution degree 2, overvoltage category II).

Output:

  • OUT: Relay: 250V AC, 8A (for resistive load), NO+NC.
  • Life expectancy for relay: Mechanical 30,000,000 operations; Electrical 100,000 operations.

Start Input:

  • Input type: Control with mechanical contact.
  • On and Off times for input pulses: Min. = 100ms, Max. = ∞.

Housing:

  • Housing type: Suitable for flush-panel mounting.
  • Dimensions: W77xH35xD71mm.
  • Weight: Approx. 198g (after packing).
  • Enclosure material: Self-extinguishing plastics.

Usage Features

The ETM1411 is designed for ease of use and installation. It features a clear 4-digit, 7-segment yellow LED display for easy readability. The front panel buttons (START, STOP, SET) provide intuitive control over the timer's functions and programming. The ability to adjust the time unit (minutes or hours) and the step for time adjustments offers flexibility for various applications. The 16 different warning tones allow for customizable audio feedback. The security menu, accessible via an access code, provides an additional layer of control over parameter changes. The device is protected by double insulation, enhancing safety.

Maintenance Features

The device is designed for durability with a self-extinguishing plastic enclosure. For cleaning, it is important to note that solvents (thinner, benzine, acid, etc.) or corrosive materials must not be used, as they can damage the device. The manual emphasizes that the guarantee will be invalidated if the device is damaged by not following the instructions. Installation and electrical connections must be carried out by qualified staff according to relevant local regulations. The device is intended for installation in control panels, and proper shielding and cable management are crucial for optimal performance and safety. Mains supply cords must meet IEC 60227 or IEC 60245 requirements, and the power supply switch should be easily accessible.

ENDA ETM1411 Series Specifications

General IconGeneral
BrandENDA
ModelETM1411 Series
CategoryTimer