ENDA ETM442 DIGITAL TIMER
Thank you for choosing ENDA ETM442 digital timer.
Supply Voltage
Order Code
230V AC +%10 -%20
ETM442
24V AC ±%10
ETM442-24AC
* 48x48mm sized.
* 2x4 digits display.
* .
* Selectable 9 different time bases between
* S
Easy to use by front panel keypad
0-99.99s and 0-9999h.
electable PNP or NPN sensor type.
* Selectable up/down counting direction for time.
* Adjustable Minimum On and Off times for pulses.
* Operation with or without memory for each output type.
* 9 different output types.
* Bottom display can be adjusted to show time unit or set value.
* Selectable functional reset.
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.
* Having CE mark according to European Norms.
ENDA
DIGITAL TIMER
PV
SV
OUT
SET
PRESET
RESET
ETM442
Input types can be adjusted as PNP or NPN in programming mode.
Minimum On and Off times for input pulses can be adjusted between 5 and 100ms.
For PNP input types, active level is 5 to 30V pulse,
For NPN input types, active level is 0 to 2V pulse.
START input
GATE input
RESET input
INPUTS
1/5
ETM442-E-03
Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
Ambient/storage temperature
Max. relative humidity
0 ... +50 °C/-25 ... +70°C (with no icing)
Rated pollution degree
TECHNICAL SPECIFICATIONS
80% up to 31 decreasing linearly 50% at 40 . °C °C
According to EN 60529 Front panel : IP60
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
Supply
230V AC +%10 -%20, 50/60Hz or 24V AC ±%10, 50/60Hz or optional 9-30V DC SMPS module.
Power consumption
Max. 5VA
2.5mm² screw-terminal connections
Wiring
Date retention
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)
EEPROM (Min. 10 years)
EN 61010-1: 2001 (pollution degree 2, overvoltage category II)
ELECTRICAL CHARACTERISTICS
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
W48xH48xD87mm
Weight
Approx. 210g (after packing)
Enclosure material
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Accuracy
± % 0.1 ± 20ms
OUTPUTS
Control output (OUT)
Relay : 250V AC, 2A (for resistive load), NO+NC
Open collector output (S.S. OUT): Max. 30V DC, 100mA
Auxiliary power supply
12V DC, max. 50mA (without regulation)
Life expectancy for relay
Mechanical 30.000.000 operation; Electrical 300.000 operation
Note : Relay and S.S.OUT outputs are in synchronization . When OUT relay is energized S.S. OUT transistor goes into saturation.
9-30V DC SMPS module
ETM442-12AC
Question and Answer IconNeed help?

Do you have a question about the ENDA ETM442 Series and is the answer not in the manual?

Summary

Technical Specifications

Environmental Conditions

Ambient/storage temperature and humidity limits, pollution degree, and height restrictions.

Electrical Characteristics

Details on supply voltage, power consumption, wiring, date retention, EMC, and safety standards.

Inputs and Outputs

Input Signal Configuration

Configuration options for START, GATE, and RESET input types and pulse timing.

Control Output and Auxiliary Supply

Specifications for the main control output (Relay/S.S.OUT) and auxiliary power supply.

Housing and Mounting

Housing and Enclosure Details

Information on housing type, dimensions, weight, enclosure material, and cleaning precautions.

Terms and Features Overview

Display and Keypad Descriptions

Defines the PV/SV displays, character height, and functions of the keypad buttons.

Dimensions and Panel Cut-out

Panel Cut-out Specifications

Provides the exact dimensions required for cutting the panel to install the timer.

Connection Diagrams and Safety

Installation and Wiring Guidance

Details on installation, wiring, safety precautions, and important notes for proper connection.

Parameter Configuration

Parameter Table Overview

Lists configurable parameters such as sensor type, time bases, output types, and security settings.

Parameter Modification Procedure

Explains how to navigate and modify numerical and non-numerical parameters using the device keys.

Output Types

TON and TOFF Timing Configurations

Details the 9 different output types with diagrams for TON (Relay On time) and TOFF (Relay Off time).

Terminal Connections

Sensor Connection Examples

Illustrates typical wiring connections for PNP and NPN sensor types to the timer's terminals.

Overview

The ENDA ETM442 Digital Timer is a versatile and user-friendly device designed for precise timing applications in control panels. Its compact 48x48mm size and clear 2x4 digit display make it suitable for a wide range of industrial environments.

Function Description

The ETM442 Digital Timer is primarily used for controlling time-based operations. It offers nine different time bases, allowing for timing intervals from 0-99.99 seconds up to 0-9999 hours, providing flexibility for various applications. Users can select between PNP or NPN sensor types, adapting the timer to different input signal requirements. The device supports both up and down counting directions for time, further enhancing its adaptability.

A key feature of the ETM442 is its ability to adjust minimum On and Off times for pulses, which is crucial for applications requiring precise pulse control. It can operate with or without memory for each of its nine output types, offering flexibility in how the timer responds to power interruptions or resets. The bottom display can be configured to show either the time unit or the set value, providing relevant information at a glance.

The timer includes a functional reset option, allowing users to easily return the device to its initial state. For enhanced security and control, parameter access can be protected on three different levels, preventing unauthorized modifications.

Usage Features

The ETM442 is designed for ease of use, featuring a front panel keypad for straightforward programming and operation. The removable screw terminals simplify electrical connections, making installation and maintenance more convenient.

The device offers various output configurations, including relay and solid-state outputs, to suit different control needs. The relay output provides NO+NC contacts for resistive loads, while the open collector output offers a solid-state option for lower power applications. An auxiliary 12V DC power supply is available for sensors, streamlining the overall system design.

The programming mode allows for detailed configuration of parameters such as time base, sensor type, counting direction, and output type. The bottom display can be toggled to show either the time unit (seconds, minutes, or hours) or the set value (ton or toff), providing immediate feedback during setup and operation. The security option menu, accessible via an access code, allows for further control over parameter programming and reset options.

The timer supports various operational modes, including delay on energization, cyclic timing (single cycle or continuous), timing on impulse (one-shot), timing after impulse (delay off), and timing on energization with memory. These diverse output types enable the ETM442 to be integrated into complex control sequences. The device's behavior can be configured to reset the timer via the keypad, a dedicated RESET input, or both, offering multiple ways to manage its operation.

Maintenance Features

The ETM442 is built with an EEPROM for data retention, ensuring that programmed settings are saved for a minimum of 10 years, even in the event of a power loss. This eliminates the need for reprogramming after power interruptions, contributing to operational efficiency.

The device is designed for flush-panel mounting according to DIN 43 700 standards, ensuring a secure and integrated fit within control panels. Its self-extinguishing plastic enclosure enhances safety.

For cleaning, it is important to avoid solvents such as thinner, benzine, acid, or corrosive materials, as these can damage the device. Adhering to these cleaning guidelines helps maintain the device's integrity and prolong its lifespan.

Installation should be carried out by qualified staff, following all relevant local regulations. The device should be protected from inadmissible humidity, vibrations, and severe soiling, and operated within its specified temperature range to ensure optimal performance and longevity. Shielded and twisted cables should be used for input and output lines not connected to the supply network, and these cables should be kept away from power cables or components to minimize interference. The CE mark indicates compliance with European Norms, assuring quality and safety standards.

ENDA ETM442 Series Specifications

General IconGeneral
TypeDigital Timer
DisplayLCD
Frequency50/60 Hz
OutputRelay
Battery BackupYes
Supply Voltage100-240V AC
Operating Temperature-10°C to +55°C
Dimensions48 x 48 mm
MountingPanel Mount

Related product manuals