FIRST TIME OPERATION
REFER TO FIGURES A, B, C, D, AND E
Read the safety instructions and this entire manual
1. Pour 32 or 64 ounces of cleaning solution in the oil solution reservoir (B)
through the ll spout
2. The Oil RX - 3000 operate s on a minimum of 50 psi of compressed air.
Connect air line to the port marked “air inlet” (2). Note the reading on the
air pressure gauge attached to the air pressure regulator. It should read
no more than 35 psi. If an adjustment is needed, pull down on the black
knob and adjust accordingly. Push up on the adjusting knob to re-lock the
regulator in position.
3. Make sure the pet cock located on the oil lter bowl is closed.
4. The Oil 3000 machine is now ready for service.
Page 5