Scenario #1
2. loose or improper wirinG
Gas Flow
Gas to Burner
Pilot Out
Pilot In
AUX1 HOT
AUX1 NEUT
AUX2 HOT
AUX2 NEUT
MH3V Gas Valve
8K1N Ignition Control Module
AUX300 – Auxiliary Control Module
Flame Sensor
EV2
EV1
GND
Battery (+)
Battery (-)
Battery Pack (4 X AA)
6VDC Power Supply
RC300
Remote Control
Dexen 8K1N - Complete IPI System
Wall Switch
(Unused)
FAN
AUX1
[EMBER LIGHTS]
AUX2
[TOP LIGHT(S)/POWER VENT]
Spark Ignition
Check the connection and continuity of all wiring supplying the voltage within the system� Use the
wiring diagram see below in Figure 9�
Figure 9: System Wiring Diagram
3. opTional wall swiTch Used, wired incorrecTly
Check the connection and continuity of the red and brown wire circuit if an optional wall switch has
been used (see figure 10)� From the factory the brown is left unused and the red wire is connected
to the battery backup�
Note - When the wall switch is ON, the remote control will not be able to turn the fireplace OFF�
Control of the AUX1, AUX2 and Fan circuits can still be done with the remote� When the wall switch
is OFF, the remote control can once again turn the fireplace ON/OFF�