9
Scenario #1
problem: piloT won’T liGhT, no spark, no modUle beeps
Possible Causes:
1� Control Module selector switch not set properly�
2� Loose or improper wiring�
3� Optional wall switch used, wired incorrectly
4� No power from junction box�
5� No power to junction box�
6� No power from 6VDC power supply�
7� Fuel setting switch on module damaged or not fully engaged into LP or NG setting�
8� Faulty module�
*Note*
• Disconnect power to the system prior to disconnecting any components by switch the ON/OFF/
REMOTE module switch to the OFF position�
• It is not recommended to operate the ignition control module with disconnected wire connec-
tions� A short could cause permanent damage�
• Applying a false flame to the pilot sensor (i�e� lighter etc�) will cause the module to go into lock-
out mode� This is due to a safety feature�
1. conTrol modUle selecTor swiTch noT seT properly
The selector switch must be in the “ON” or “REMOTE” setting for the unit to operate� Isolate the re-
mote from the system when troubleshooting� Switch to “ON” to test operation� See Figure 8 below�
Switch to “ON” to test operation
Figure 8: Control Module - Selector Switch Setting