Damp Pro
SHOULD YOU ENCOUNTER ANY PROBLEMS
INSTALLING THIS UNIT, CONTACT YOUR SUPPLIER
6
Pre - Installation Checklist
Does the unit fit through the loft hatch?
Check there are no obstructions in the hallway or landing where the
diffuser is to be fitted and in the loft space above.
Ensure the loft has adequate cross-flow ventilation to provide a
supply of fresh air to the unit.
Check that all partition walls are intact. Seek building advice if any
are missing or broken.
Check for flued appliances drawing air from the loft, the user should
be made aware of any of these.
Check that any flue passing through the loft is undamaged. Seek
building advice if any are damaged or broken.
Repair any ceiling gaps which allow air leakage into the loft.
Ensure any loft water storage tanks are covered and sealed.
About the ventilation unit
The damppro loft unit is a Positive Input Ventilation (PIV) unit which
creates fresh and healthy living environments by supplying filtered air
into a property at a continuous rate through a ceiling mounted diffuser.
The diffuser is normally installed in a hallway or landing area.
The units have been developed to improve indoor air quality and resolve
condensation and mould problems. They are designed to operate
continuously for 5 years with no requirement for maintenance other
than general cleaning the filter must be replaced after 5 years usage.
In conditions between 19°C - 25°C the units will increase air flow rate
by 10%. In hot conditions above 25°C the units will temporarily switch
off to avoid bringing hot air into the property from the loft space.