Safety and operating instructions
20 © Construction Tools GmbH | 33905146 01 | 2019-09-05
Original Instructions
3.4 Applications
Field Type of application
General construction work Trenchwork for utilities,
foundation work
Demolition Heavily reinforced con-
crete, demolition of power
stations and bridges
Rock mining/breaking Primary breaking
Secondary breaking,
bench levelling foundation
work
3.5 Guarantee
The guarantee or product liability will be invalidated by
the following:
• Use other than intended
• Maintenance work not being carried out or being
carried out incorrectly
• The use of incorrect consumables
• The use of non-approved parts
• Damage due to wear
• Damage due to improper storage
• Changes not carried out by or in consultation with
the manufacturer
3.6 Removing the packaging
n
Remove all the packaging material.
n
Dispose of it in accordance with the applicable provi-
sions.
n
Check that the delivery is complete.
n
Check the delivery for visual damage.
n
If any defects are found, consult the Epiroc Customer
Center / dealer in your area.
3.7 Scope of delivery
The hydraulic breaker is delivered complete with:
• Hydraulic breaker
• Test gauge lower wear bush
• Safety and Operating instructions
• Spare parts list
• EC Declaration of Conformity
Accessories as ordered:
• Working tool
• Hoses
• Service box
Special accessories as ordered:
• e.g. adapter plate with Allen screws and pairs of lock
washers
• e.g. base plate to construct an adapter plate with
Allen screws and pairs of lock washers
• e.g. hydraulic fittings for the carrier
• e.g. piston retainer
• e.g. calliper upper wear bush

Table of Contents