Safety and operating instructions
Hydraulic breakers
SB
52, 102, 152, 202, 302, 302Tunnel, 452, 452Tunnel, 552
© Construction Tools PC AB | 9800 0648 01 | 2018-01-01
Original instructions

Table of Contents

Other manuals for Epiroc SB 102

Questions and Answers

  • M
    marygravesAug 12, 2025
    Why Epiroc Power Tool hydraulic breaker does not start?
    • T
      thomasdavisAug 12, 2025
      The hydraulic breaker might fail to start due to several reasons: * The pressure and tank hoses may be mixed up. Ensure that the connections are correct. * The shut-off valve in the pressure or tank hoses might be closed. Check and open the valve. * Defective couplings may be blocking the pressure and tank hoses. Inspect the couplings and replace any defective valves. * The operating pressure may be too low. Check the carrier engine speed, pump delivery, and pressure relief valve. Also, verify the operating pressure, adjust settings, and replace defective parts if necessary. * The return pressure may be too high. Check and lower the return pressure.
  • S
    sjohnstonAug 21, 2025
    What to do if Epiroc Power Tool has oil leaks?
    • A
      alexanderrobertAug 21, 2025
      If you observe oil leaks in your Epiroc Power Tool, it is likely due to leaking or damaged seals. The solution is to replace the seals.
  • J
    jacksonkevinAug 31, 2025
    How to fix low impact force on Epiroc Power Tool?
    • M
      Maria AndersonAug 31, 2025
      Low impact force in your Epiroc Power Tool can be caused by gas pressure being too low, or by whipping and pulsing hoses. Check the gas pressure and fill the accumulator to resolve this issue.