15
NOTE: Equipment damage!
Equalization may increase battery voltage to the
level damaging to sensitive DC loads. Ensure that
all load allowable input voltages are greater than
the equalizing charging set point voltage.
NOTE: Equipment damage!
Over-charging and excessive gas precipitation
may damage the battery plates and activate
material shedding on them. Too high an
equalizing charge or for too long may cause
damage. Please carefully review the specific
requirements of the battery used in the system.
Certain types of batteries benefit from periodic equalizing charge,
which can stir the electrolyte, balance battery voltage and complete
chemical reaction. Equalizing charge increases the battery voltage,
higher than the standard complement voltage, which gasifies the
battery electrolyte.
If the battery is being over discharged, the solar controller will
automatically turn to equalize charging stage, and the equalize stage
remain 120mins. Equalize charge and boost charge are not carried out
constantly in a full charge process to avoid too much gas precipitation
or overheating of battery.