EasyManua.ls Logo

Epsolar MT50 - Battery Charging Settings

Epsolar MT50
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
Battery charging
setting
Sealed
Gel
Flooded
User
Over voltage
disconnect voltage
16.0V
16.0V
16.0V
9~17V
Charging limit
voltage
15.0V
15.0V
15.0V
9~17V
Over voltage
reconnect voltage
15.0V
15.0V
15.0V
9~17V
Equalize charging
voltage
14.6V
——
14.8V
9~17V
Boost charging
voltage
14.4V
14.2V
14.6V
9~17V
Float charging
voltage
13.8V
13.8V
13.8V
9~17V
Boost reconnect
charging
voltage
13.2V
13.2V
13.2V
9~17V
Low voltage
reconnect voltage
12.6V
12.6V
12.6V
9~17V
Under voltage
warning reconnect
voltage
12.2V
12.2V
12.2V
9~17V
Under voltage
warning voltage
12.0V
12.0V
12.0V
9~17V
Low voltage
disconnect voltage
11.1V
11.1V
11.1V
9~17V
Discharging limit
voltage
10.6V
10.6V
10.6V
9~17V
Equalize duration
120min
——
120min
0~180min
Boost duration
120min
120min
120min
10~180min.

Other manuals for Epsolar MT50