Epson Artisan 810/835/837/710/725/730/Epson Stylus Photo PX810FW/TX810FW/PX820FWD/TX820FWD/PX830FWD/PX710W/TX710W/PX720WD/TX720WD/PX730WD/TX730WD
Revision G
Artisan 835/725/PX820FWD/TX820FWD/PX720WD/TX720WD
  Disassembly/assembly 268
Confidential
8. While lifting the Upper Housing, pull out the Panel FFC from the hole of the 
Upper Housing and remove the Upper Housing.
Figure 8-12.  Removing the Upper Housing (5)
9. Remove the Panel Unit from the Upper Housing. (See 8.3.2.3 Panel Unit 
Step8 (p269) and after.)
8.3.2.3  Panel Unit
 Parts/Components need to be removed in advance:
Scanner Unit/Upper Left Housing/Paper Guide Top Assy
 Removal procedure
1. Remove the screw (x1) and release the grounding wire. (See 8.3.2.2 Upper 
Housing Step1 (p266).)
2. Open the Panel Unit. (See Fig. 8-8 (p267).)
3. Release the hook (x1) on the rear of the Panel Unit, and remove the Panel 
Rear Cover. (See 
8.3.2.2 Upper Housing Step3 (p267).)
4. Peel off the Panel FFC and the ferrite core that are secured to the Panel Shield 
Plate with the double-sided tape, and disconnect the Panel FFC from the 
connector on the Panel Unit. (See 
8.3.2.2 Upper Housing Step4 (p267).)
5. Pull out the ferrite core from the Panel FFC. (See 8.3.2.2 Upper Housing 
Step5 (p267).)
6. Remove the screws (x2) that secure the Right Hinge.
Figure 8-14.  Removing the Panel Unit (1)
 Tighten the screws in the order shown in Fig. 8-10.
 Secure the Panel FFC and ferrite core to the Panel Shield Plate 
with double-sided tape. (See 
Fig. 8-9 (p267).)
 Fold the Panel FFC at the fold line, and route it along the 
marking on the Panel Shield Plate.
Figure 8-13.  Routing the Panel FFC
A D J U S T M E N T
R E Q U I R E D
After removing/replacing the Upper Housing, make the specified 
adjustments. (See 
8.4 "Adjustment" (p274).)
Upper Housing
Hole of Upper Housing
Panel FFC
Panel Unit
This section describes the disassembly/reassembly procedures of the 
Panel Unit for Artisan 725/PX720WD/TX720WD.
The disassembly/reassembly procedures for Artisan 835/
PX820FWD/TX820FWD are the same as those for Artisan 810/
PX810FW/TX810FW, therefore, see 
4.2.4.1 "Panel Unit" (p124) for 
the procedures.
Panel Unit
C.B.P. 3x10 (black) (6±1Kgfcm)
Right Hinge