EPSON Stylus CX4900/CX4905/CX5000/DX5000/DX5050/CX5900/CX6000/DX6000/DX6050 Revision A
ADJUSTMENT Adjustment Except Adjustment Program 185
14. Accede to following steps until you’ve completed the right side PG
adjustment.
Figure 5-21. Right Side PG Adjustment
15. Tighten the screw securing for Parallel Adjustment Lever (Right) temporary.
16. Set the thickness gauge at position shown by Figure 5-15 again.
17. Accede to following steps to check left side PG again.
Figure 5-22. Right/Left Sides PG Checking
18. Tighten both screws completely.
START
Move the Carriage Unit by
using the Timing Belt.
Thickness
Gauge moves?
One notch up the Parallel
Adjustment Lever (Right).
One notch down the Parallel
Adjustment Lever (Right).
Move the Carriage Unit by
using the Timing Belt.
Thickness Gauge
moves?
Advance to Step 15.
Step 13
Yes
Yes
No
No
Note : “Down” means PG
(Platen Gap) wide.
Note : “Up” means PG (Platen Gap) narrow.
START
Move the Carriage Unit by
using the Timing Belt.
Thickness Gauge
moves?
One notch up the Parallel
Adjustment Lever (Left).
Move the Carriage Unit by
using the Timing Belt.
Thickness Gauge
moves?
Re-adjust from
the beginning.
One notch down the Parallel
Adjustment Lever (Left).
Advance to Step 18.
Yes
Yes
No
Note : “Up” means PG (Platen Gap) narrow.
Note : Down” means PG
(Platen Gap) wide.
No
Re-adjust from
the beginning.