EPSON Stylus CX4900/CX4905/CX5000/DX5000/DX5050/CX5900/CX6000/DX6000/DX6050 Revision A
TROUBLESHOOTING Error Indications and Fault Occurrence Causes 92
Note : “–”: No change
Note *1: Stylus CX4900/CX4905/CX5000/DX5000/DX5050 only
*2: Stylus CX5900/CX6000/DX6000/DX6050 only
Table 3-3.  Error Indications and Fault Occurrence Causes
Printer Status Communication Error Ink Low Double Feed Paper Out 
LEDs*
1
Power — — — —
Error — — On On
Ink — Blink Off Off
Memory 
Card
1 — — — —
2 — — — —
3 — — — —
7-seg. — — — —
Paper 
Type
1 — — — —
2 — — — —
Paper 
Size
1 — — — —
2 — — — —
Fit to Page — — — —
LCD*
2
— I-01 E-05 E-03
Status monitor 3 
message
Fault 
Occurrence 
Cause
This error is detected when the SPC 
cannot communicate with the PC 
correctly.
This error is detected when the ink 
consumption amount reaches about 90%.
Note :
Even if this error is indicated on the STM3, you 
can continue printing until I/C becomes Replace 
Ink Cartridge condition. However, the Head 
Cleaning operation cannot be done so that the 
remaining ink is low condition.
This error is detected at re-sending of 
paper for double-sided printing when 
paper length is determined to be other than 
default value.
This error is detected when the top of a 
paper is not detected with the PE Sensor in 
the paper loading sequence.
Reference Page
“3-6 Check point for communication error 
according to each phenomenon” (p.95).
---
“3-8 Check point for double feed error 
according to each phenomenon” (p.99).
“3-9 Check point for paper out error 
according to each phenomenon” (p.100).