Epson Stylus Photo R280/R285/R290/Epson Artisan 50/Epson Stylus Photo T50/T59/T60/P50 Revision C
Chapter 4 Disassembly/Assembly 4.4.4 APG Unit (Disassembling the Printer Mechanism) 79
Confidential
 Lubrication is required. See the page given below for the 
lubrication information.
Lubrication of APG Unit (p.125)
 Install the APG Unit following the procedure below. 
1. Put a pin (thinner than Ø2mm) through the positioning 
holes of the Main Frame and the right PG Cam on the CR 
Shaft.
Figure 4-57.  Reinstalling the APG Unit (1)
2. Put the pin through the positioning holes of the Spur gear 
28.8 and the APG Unit. 
Figure 4-58.  Reinstalling the APG Unit (2)
3. Install the APG Unit to the Main Frame. 
Figure 4-59.  Reinstalling the APG Unit (3)
4. Check that the hooks ( ) are attached to the positioning 
holes of the Main Frame, then screw the APG Unit. 
Figure 4-60.  Reinstalling the APG Unit (4)
 Tighten the screws in the order given in Fig.4-55 (p.78).