EPSON Stylus Photo R260/R265/R270, R360/R380/R390 Revision B
Disassembly/Assembly Disassembly of the Printer Mechanism 107
 Lubrication is required. See the page given below for the 
lubrication information.
"6.1.3 Lubrication (p.131)"
 Before attaching the right PG cam, remove the APG Unit and 
install the cam matching its phase with the APG Unit. 
(See Fig.4-91, Fig.4- 92)
 When attaching the spring (2) and the washer for the Right PG 
Cam to the CR Shaft, make sure to attach them to the 
positioning slits on the CR Shaft. (See Fig.4-146)
 When installing the Timing Belt, make sure that it is not 
twisted and the lumpy side comes to the inner side.
Figure 4-151.  Reinstalling the Timing Belt
 When installing the CR Unit, hook the Guide part to the Main 
Frame. 
Figure 4-152.  Reinstalling the CR Unit 
A D J U S T M E N T
R E Q U I R E D
Whenever the CR Unit is removed or replaced, the required 
adjustments must be carried out. 
• See “Table 5-4. Adjustment Items (p.116)” in Chapter 5
Lumpy side 
(Inner side)
Flat side 
(Outer side)
Up
Lumpy on both inner/
outer side 
 CR Unit
Guide Part
C H E C K
P O I N T
Remove the Cartridge Cover following the steps below. The Hinge, 
Cover Cartridge need to be cut with a nipper or similar tool to be 
removed. Therefore, whenever replacing the Cartridge Cover, the 
Hinge, Cover Cartridge also must be replaced with a new one.
1. Cut the convex portion of the Hinge, Cover Cartridge with a 
nipper or similar tool.
2. Disengage the hook from the opening made by the cut and remove 
the Hinge, Cover Cartridge.
3. Remove the Cartridge Cover pulling out its two guide pins.
Figure 4-153.  Removing the Cartridge Cover
 
: cut position
Hinge, Cover 
Cartridge
Convex 
portion
Hook
Cartridge Cover
 
: Guide Pin
Hook
Cut convex portion 
of the hinge
Right side view 
of the hinge
[Right rear of the CR Unit]