Thank you very much for purchasing our air conditioner. Please read this owen's manual carefully before
using your air conditioner.
Model No.: 19S-EACH9R1W/C 19S-EACH9R2W/C 19S-EACH12R1W/C
19S-EACH12R2W/C 19S-EACH18R2W/C 19S-EACH24R2W/C
17S-EACH36R2W/C
User Manual
19SEER Mini Split Air Conditioner
Question and Answer IconNeed help?

Do you have a question about the EQK 19S-EACH9R1W/C and is the answer not in the manual?

Overview

The EQK 19SEER Mini Split Air Conditioner is a high-efficiency portable air conditioning system designed for domestic environments. This user manual provides comprehensive instructions for installation, operation, and maintenance, ensuring reliable service for many years.

Function Description

The EQK Mini Split Air Conditioner offers multiple operating modes to suit various comfort needs:

  • Cooling Mode: This function cools the room and reduces air humidity simultaneously. Users can set a desired temperature lower than the room temperature.
  • Heating Mode (for heating pump models): This function heats the room. Users can set a desired temperature higher than the room temperature. The appliance may activate a defrost cycle during heating to maintain efficiency, which typically lasts 2-10 minutes. During defrosting, the indoor fan stops operation. A forced defrosting can be initiated by pressing the ECO button 10 times within 8 seconds in heating mode.
  • Dry Mode: This mode reduces air humidity to enhance comfort. It operates automatically based on pre-settings.
  • Fan Mode: This mode provides air ventilation only, allowing users to select various fan speeds (Auto, Mute, Low, Low-Mid, Mid, Mid-High, High, Turbo).
  • Auto Mode: In this mode, the air conditioner automatically adjusts its operation based on the room temperature.
  • ECO Mode: This energy-saving mode automatically optimizes operation to conserve energy. It is available in both cooling and heating modes.
  • Sleep Function: This pre-setting automatic operating program adjusts settings for comfortable sleep and automatically reverts to the previous mode after 10 hours.
  • Display ON/OFF: This function allows users to switch the LED display on the indoor unit panel on or off.
  • I FEEL Function (Optional): This feature enables the remote control to measure the temperature at its current location and send this signal to the air conditioner for optimized comfort. It automatically deactivates after 2 hours.
  • Self-Clean Function (Optional, for some heating pump inverter appliances): This function helps remove accumulated dirt and bacteria from the indoor evaporator. It runs for about 30 minutes and then returns to the pre-setting mode. It is recommended to use this function every 3 months.
  • 8°C Heating Function (Optional): This function automatically starts heating mode when the room temperature drops below 8°C (46°F) and returns to standby when it reaches 9°C (48°F). It cancels automatically if the room temperature is higher than 18°C (64°F).
  • Child-Lock Function: This function disables all buttons on the remote control to prevent accidental changes.
  • Mute Function: This function sets the indoor unit to operate at the lowest fan speed for quiet operation. It cannot be activated under dry mode.
  • Gentle Wind Function (depending on models): Activated by pressing FAN + MUTE.
  • Health Function (depending on models): Activated by pressing SLEEP + DISPLAY.
  • Anti-Mildew Function: Activated by pressing ANTI-MILDEW.
  • Self-Clean Function (depending on models): Activated by pressing SWING + SWING <>.

Important Technical Specifications

The EQK Mini Split Air Conditioner is available in various capacities (Btu/h) and models: 19S-EACH9R1W/C, 19S-EACH9R2W/C, 19S-EACH12R1W/C, 19S-EACH12R2W/C, 19S-EACH18R2W/C, 19S-EACH24R2W/C, and 17S-EACH36R2W/C.

  • Operating Temperature Range:
    • Room temperature: 0°C~27°C (Heating), 17°C~32°C (Cooling), 15°C~50°C (Dry, T1 climate), 15°C~55°C (Dry, T3 climate).
    • Outdoor temperature: -15°C~24°C (Low temperature heating: -20°C~24°C), -15°C~50°C (Low temperature cooling: -15°C~50°C).
  • Refrigerant Type: R22/R410A or R32, depending on the model.
  • Pipe Length and Additional Refrigerant:
    • Standard charge pipe length: 5m (9K-12K, 18K-36K) or 7.5m (North American models).
    • Maximum distance between indoor and outdoor unit: 15m (9K-12K) or 25m (18K-36K).
    • Additional refrigerant charge: 20g/m (9K-12K), 15g/m (R32 9K-12K), 30g/m (18K-36K), 25g/m (R32 18K-36K).
    • Max. difference in level between indoor and outdoor unit: 10m for all models.
  • Torque Parameters for Flare Nuts:
    • 1/4" (Φ 6.35): 18-20 N·m (24.4-27.1 lbf·ft, 2.4-2.7 kgf·m).
    • 3/8" (Φ 9.52): 30-35 N·m (40.6-47.4 lbf·ft, 4.1-4.8 kgf·m).
    • 1/2" (Φ 12): 45-50 N·m (61.0-67.7 lbf·ft, 6.2-6.9 kgf·m).
    • 5/8" (Φ 15.88): 60-65 N·m (81.3-88.1 lbf·ft, 8.2-8.9 kgf·m).
  • Electrical Specifications (Dedicated Distribution Device and Wire):
    • Maximum Operating Current (A) | Minimum Wire Cross-sectional Area (mm²) | Specification of Socket or Switch (A) | Fuse Specification (A)
    • <8 | 0.75 | 10 | 20
    • 8 and ≤10 | 1.0 | 10 | 20

    • 10 and ≤15 | 1.5 | 16 | 32

    • 15 and ≤24 | 2.5 | 25 | 32

    • 24 and ≤28 | 4.0 | 32 | 64

    • 28 and ≤32 | 6.0 | 40 | 64

Usage Features

  • Remote Control: The unit comes with a remote control featuring a clear display for various settings and functions, including mode selection, temperature adjustment, fan speed, timer, sleep, display on/off, swing, I FEEL, mute, anti-mildew, gentle wind, health, and child-lock. The remote control uses 2 AAA (1.5V) batteries.
  • Timer Function: Allows users to set automatic switch-on (TIMER ON) and switch-off (TIMER OFF) times.
  • Swing Function: Controls the horizontal and vertical flaps to adjust airflow direction. Horizontal flaps swing up and down, while vertical deflectors swing left and right.
  • Turbo Function: Activates quick cooling or heating with the highest fan speed for strong airflow.
  • Emergency Button: Located on the indoor unit's electronic control box, this button allows basic operation (Cooling, Heating, Off) if the remote control fails.
  • Indoor Display: Features LEDs for Timer, temperature, error codes, Sleep mode, and power status.
  • Installation Flexibility: Offers three optional piping modes for indoor units to accommodate different wall hole positions.
  • Quiet Operation: The MUTE function reduces fan speed for a quieter environment.

Maintenance Features

  • Filter Cleaning: The air filter should be cleaned regularly to prevent dust accumulation and maintain efficiency. It can be easily removed, washed with soapy water, and air-dried.
  • Unit Cleaning: The indoor unit surface can be wiped with a soft dry cloth or a wet cloth dipped in neutral detergent. Volatile liquids like thinner or gasoline should not be used.
  • Long-Term Storage: When not in use for an extended period, remove batteries from the remote control and disconnect the power supply.
  • Pre-Season Check: Before restarting after a long shutdown, clean the unit and filter, check for obstructions at air inlets/outlets, ensure the drain pipe is clear, and install remote control batteries.
  • Self-Clean Function: Helps maintain the cleanliness of the indoor evaporator.

Safety Precautions

The manual emphasizes several safety rules for both installers and users:

  • Installation should be performed by professional or qualified personnel.
  • Ensure proper grounding and use a suitable fuse or overload protection device.
  • Do not obstruct air inlets or outlets.
  • Avoid direct and prolonged exposure to cold air.
  • Disconnect power before cleaning or maintenance.
  • Do not bend, tug, or compress the power cord.
  • Do not use extensions or gang modules.
  • Do not touch the appliance with wet hands or bare feet.
  • Keep children away from the working area during installation and prevent them from playing with the appliance.
  • Dispose of batteries and packaging materials properly as sorted municipal waste.
  • In case of smoke or burning smell, immediately cut off power and contact the Service Center.
  • Repairs should only be carried out by an authorized Service Centre.