STORAGE AND TRANSPORTATION REGULATIONS
Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range
from +5 ˚С up to +40 ˚С and relative humidity up to 70 %.
Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and
sealing deformation.
The appliance can be installed in a bathroom, but in the
allowed area according IEC60364 standard (out ot volumes
1, 2, which means at least 60cm far from bath or shower
space).
2250
2250
750
750
600
600
R 600
1
2
3
The fan is designed for wall or ceiling mounting with direct air exhaust through a cylindrical tube ending with protection to
avoid ingress of water (Fig.1)
It is recommended to avoid 90° bends or cross section reduction. It is advisable to use rigid rather than flexible air ducts
(1.5 m max in a straight line)
For detailed technical informations, please check : http://www.erp-equation.com/aerators