15.
THE APPLIANCE DOES NOT STOP TO OPERATE WHEN THE DOOR IS
OPEN :-
a. REPAIR requirement Possible malfunction:
a. Faulty door micro-switch
b. Damaged spring on the door micro-switch rod
c. Calcars on the fitting point of door micro-switch
rod
16.
THE APPLIANCE STARTS AGAIN WHEN THE PROGRAM HAS BEEN
TERMINATED :-
a. REPAIR requirement Possible malfunction:
a. Faulty timer – switch.
17.
CREVICE ON THE SURFACE OF THE HEATING ELEMENT :-
a. REPAIR requirement Possible malfunction:
a. Damaged heating element.
18.
THE WATER TEMPERATURE GETS VERY HIGH :-
a. REPAIR requirement Possible malfunction:
a. Faulty temperature thermostat.
19.
THE SALT INDICATOR LIGHTS ON WHILE THE SALT CONTAINER IS
FILLED UP :-
a. REPAIR requirement Possible malfunction:
a. Faulty water softener device
20.
THE APPLIANCE SPENDS THE SALT OF THE SALT CONTAINER ,
UNUSUALLY FAST :-
a. REPAIR requirement Possible malfunction:
a. Faulty water softener device
21.
THERE IS NO POWER , THE APPLIANCE IS INACTIVE :-
a. There is not electrical supply from the
socket.
Check the socket. If it is out of order, call an
electrician.