Accessories
1. Clean the accessories with a slightly damp cloth and mild soap. Use a brush for
areas that are hard to reach.
2. Unclog the twin rotary nozzle (4) or 5-in-1 nozzle (8) with the cleaning needle (20)
(Fig. 24). To do so, insert the cleaning needle into the nozzle opening and move
back and forth.
3. Disassemble the
water inlet hose adaptor (19)
(Fig. 25).
Rinse the parts with clear
water (Fig. 26).
4. Drain and wash out the foam cannon (9) at the end of the working session. Wash
out the detergent bottle (9d).
03
Decalcication
From time to time – according to the nature of your tap water – calcium deposits
form in the machine and accessories. The strength of the deposits (and thus the
frequencyofdecalcication)dependsuponthedegreeofhardnessofthewater
andhowoftenthemachineisused.Checkwithyoursupplierinordertondthe
hardness of the water in your area.
NOTE:
Useamixtureofwaterandcitricacidorvinegarfordecalcication.
These substances are readily biodegradable and environmentally friendly!
1. Makeamixtureofonepartofpropervinegarandtwopartshotwater(≤50°C)in
a suitable container, e. g. in a bowl.
2. Lay the detachable accessories in the mixture.
3. Leave the accessories in the mixture for approximately 12 hours.
4.
Rinse the accessories with clear water.
04
Maintenance
Before and after each use, check the machine and accessories for wear and damage.
If required, exchange them for new ones as described in this instruction manual.
Observe the technical requirements.
5063022018892-EBPW3000-PressureWasher-UM-V03.indd 325063022018892-EBPW3000-PressureWasher-UM-V03.indd 32 09-11-2022 14:09:0809-11-2022 14:09:08
33
05
UK plug replacement
WARNING!
Never connect live or neutral wires to the earth terminal of
the plug, which is marked with E.
Only fit an approved 13 Amp BS 1363 or BS 1363/A plug and the
correctly rated fuse. If in doubt, consult a
electrician.
If a moulded plug is fitted and has to be removed take great care in
disposing of the plug and severed cable, it must be destroyed to prevent
engaging into a socket.
If you need to replace the plug, then follow the instructions below.
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Blue – Neutral Brown – Live
As the colours of the wire in the mains lead of this product may not correspond with
the coloured marking identifying the terminals in your plug, proceed as follows. The
wire, which is coloured blue, must be connected to the terminal, which is marked with
N or coloured black. The wire, which is coloured brown, must be connected to the
terminal, which is marked L or coloured red.
5063022018892-EBPW3000-PressureWasher-UM-V03.indd 33 09-11-2022 14:09:08
13 AMP fuse
approved to BS 1362
Brown L (Live)
Cable grip
Connect green/yellow wire to
terminal E(Protective earth )
Connect Blue to N
(Neutral)
Outer sleeve
96456_IM_Erbauer 3000_EU.indb 3396456_IM_Erbauer 3000_EU.indb 33 2023/3/27 上午11:082023/3/27 上午11:08